This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
en:infra-convert:user:cadexp:nx_10 [2021/06/22 16:08] me |
en:infra-convert:user:cadexp:nx_10 [2023/11/17 19:23] (current) me [DXF/DWG export] |
||
---|---|---|---|
Line 7: | Line 7: | ||
</WRAP> | </WRAP> | ||
- | ====== NX (ab Version 10) ====== | + | ====== NX (from version 10) ====== |
---- | ---- | ||
Line 39: | Line 39: | ||
Recommended configurations: | Recommended configurations: | ||
+ | |||
+ | {{page>en:infra-convert:user:cadexp:dxf_dwg_version_note}} | ||
|< 100% 7.5% 22.5% 70%>| | |< 100% 7.5% 22.5% 70%>| | ||
- | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Drafting preferences | **File** > **Drafting preferences** > **View** > **Workflow** > **Border** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid629526|{{:en:icon_link.png?8|}}]]\\ └ Display: **Off**\\ \\ Version 10: Version 12:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_001.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_001.png?direct&0x100|}} | | + | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Drafting preferences | **File** > **Drafting preferences** > **View** > **Workflow** > **Border** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid629526|{{:en:icon_link.png|}}]]\\ └ Display: **Off**\\ \\ Version 10: Version 12:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_001.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_001.png?direct&0x100|}} | |
- | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_108.png?nolink&50 |}} ^ Load Settings | **File** > **Export** > **AutoCAD DXF/DWG…** > **Load Settings** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366:xid454319|{{:en:icon_link.png?8|}}]]\\ └ Load From: Settings file (*.def)*\\ \\ * The configuration file should contain the following value assignment: [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid1396811|{{:en:icon_link.png?8|}}]]\\ └ UGI_GDT_EXPORT_AS_BLOCK = NO | | + | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_108.png?nolink&50 |}} ^ Load Settings | **File** > **Export** > **AutoCAD DXF/DWG…** > **Load Settings** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366:xid454319|{{:en:icon_link.png|}}]]\\ └ Load From: Settings file (*.def)*\\ \\ * The configuration file should contain the following value assignment: [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid1396811|{{:en:icon_link.png|}}]]\\ └ UGI_GDT_EXPORT_AS_BLOCK = NO\\ \\ The path to the configuration file for the DXF/DWG translator can also be set once by environment variable NX_DXFDWG_DEF. [[https://docs.plm.automation.siemens.com/tdoc/nx/1899/nx_help#uid:xid1128422:index_dataexchange:xid1579771|{{:de:icon_link.png|}}]] | |
- | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_102.png?nolink&50 |}} ^ Input and Output | **File** > **Export** > **AutoCAD DXF/DWG…** > **Input and Output** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366:xid454319|{{:en:icon_link.png?8|}}]]\\ └ Export To: **DXF** or **DWG**\\ └ Export As: **2D**\\ \\ Version 10: Version 12: Version 1899:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_002.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_002.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_1899_001.png?direct&0x100|}} | | + | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_102.png?nolink&50 |}} ^ Input and Output | **File** > **Export** > **AutoCAD DXF/DWG…** > **Input and Output** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366:xid454319|{{:en:icon_link.png|}}]]\\ └ Export To: **DXF** or **DWG**\\ └ Export As: **2D**\\ └ Output to: **Modeling**\\ └ Output to: **Layout***\\ \\ * #@IC_HTML@# Per required\\ \\ Version 10: Version 12: Version 1899:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_002.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_002.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_1899_001.png?direct&0x100|}} | |
- | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_103.png?nolink&50 |}} ^ Data to Export | **File** > **Export** > **AutoCAD DXF/DWG…** > **Data to Export** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366:xid454319|{{:en:icon_link.png?8|}}]]\\ └ Model Data/Drawing: **Drawing**\\ \\ Version 10: Version 12: Version 1899:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_003.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_003.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_1899_002.png?direct&0x100|}} | | + | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_103.png?nolink&50 |}} ^ Data to Export | **File** > **Export** > **AutoCAD DXF/DWG…** > **Data to Export** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366:xid454319|{{:en:icon_link.png|}}]]\\ └ Model Data/Drawing: **Drawing**\\ \\ Version 10: Version 12: Version 1899:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_003.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_003.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_1899_002.png?direct&0x100|}} | |
- | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_104.png?nolink&50 |}} ^ Options | **File** > **Export** > **AutoCAD DXF/DWG…** > **Options** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366:xid454319|{{:en:icon_link.png?8|}}]]\\ └ DXF/DWG Revision: **2018-2020**\\ └ Export Spline As: **Spline**\\ └ Remove Overlapping Entities: **No**\\ └ Scale Option: **No Scale**\\ └ Scale Value: **1.0000**\\ \\ Version 10: Version 12: Version 1899:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_004.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_004.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_1899_003.png?direct&0x100|}} | | + | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_104.png?nolink&50 |}} ^ Options | **File** > **Export** > **AutoCAD DXF/DWG…** > **Options** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366:xid454319|{{:en:icon_link.png|}}]]\\ └ DXF/DWG Revision: see "General - DXF/DWG version" above\\ └ Export Spline As: **Spline**\\ └ Remove Overlapping Entities: **No**\\ └ Scale Option: **No Scale**\\ └ Scale Value: **1.0000**\\ \\ Version 10: Version 12: Version 1899:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_004.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_004.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_1899_003.png?direct&0x100|}} | |
- | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_105.png?nolink&50 |}} ^ Fonts | **File** > **Export** > **AutoCAD DXF/DWG…** > **Fonts** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366:xid454319|{{:en:icon_link.png?8|}}]]\\ └ Text Width: **Use NX Aspect Ratio**\\ └ latin_extended: **isocp.shx**\\ \\ Version 10: Version 12: Version 1899:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_005.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_005.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_1899_004.png?direct&0x100|}} | | + | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_105.png?nolink&50 |}} ^ Fonts | **File** > **Export** > **AutoCAD DXF/DWG…** > **Fonts** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366:xid454319|{{:en:icon_link.png|}}]]\\ └ Text Width: **Use NX Aspect Ratio**\\ └ Text Width (alternative): **Specify Width Factor**, Width Faktor: **1**\\ └ latin_extended: **isocp.shx**\\ \\ Version 10: Version 12: Version 1899:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_005.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_005.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_1899_004.png?direct&0x100|}} | |
\\ | \\ | ||
Line 57: | Line 59: | ||
|< 100% 7.5% 22.5% 70%>| | |< 100% 7.5% 22.5% 70%>| | ||
- | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Drafting Preferences | **File** > **Drafting Preferences** > **View** > **Workflow** > **Border** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid629526|{{:en:icon_link.png?8|}}]]\\ └ Display: **Off**\\ \\ Version 10: Version 12:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_001.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_001.png?direct&0x100|}} | | + | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Drafting Preferences | **File** > **Drafting Preferences** > **View** > **Workflow** > **Border** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid629526|{{:en:icon_link.png|}}]]\\ └ Display: **Off**\\ \\ Version 10: Version 12:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_001.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_001.png?direct&0x100|}} | |
- | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Files | **File** > **Export** > **Export to IGES Options** > **Files** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid434343|{{:en:icon_link.png?8|}}]]\\ └ Export from: **Drawings**\\ └ Export to: **IGES file**\\ \\ Version 10:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_011.png?direct&0x100|}} | | + | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Files | **File** > **Export** > **Export to IGES Options** > **Files** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid434343|{{:en:icon_link.png|}}]]\\ └ Export from: **Drawings**\\ └ Export to: **IGES file**\\ \\ Version 10:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_011.png?direct&0x100|}} | |
- | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Data for Export | **File** > **Export** > **Export to IGES Options** > **Data for Export** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid434343|{{:en:icon_link.png?8|}}]]\\ └ Export: **Selected Drawings**\\ \\ Version 10:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_012.png?direct&0x100|}} | | + | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Data for Export | **File** > **Export** > **Export to IGES Options** > **Data for Export** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid434343|{{:en:icon_link.png|}}]]\\ └ Export: **Selected Drawings**\\ \\ Version 10:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_012.png?direct&0x100|}} | |
- | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Advanced | **File** > **Export** > **Export to IGES Options** > **Advanced** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid434343|{{:en:icon_link.png?8|}}]]\\ └ NX 3D to 2D options > Enclose facet body: **Yes**\\ └ NX 3D to 2D options > Convert GDT as a group: **No**\\ \\ Version 10:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_013.png?direct&0x100|}} | | + | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Advanced | **File** > **Export** > **Export to IGES Options** > **Advanced** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid434343|{{:en:icon_link.png|}}]]\\ └ NX 3D to 2D options > Enclose facet body: **Yes**\\ └ NX 3D to 2D options > Convert GDT as a group: **No**\\ \\ Version 10:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_013.png?direct&0x100|}} | |
\\ | \\ | ||
Line 71: | Line 73: | ||
|< 100% 7.5% 22.5% 70%>| | |< 100% 7.5% 22.5% 70%>| | ||
- | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Export PDF | **File** > **Export** > **PDF...** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128416:index_working_with_files:id1354112:file_fil_exp_pdf_op|{{:en:icon_link.png?8|}}]]\\ └ Source: Select sheets\\ └ Colors: **Black on white**\\ └ Size: **Original size**\\ └ Output text: **Text**\\ └ Export grid images to drawing: **Yes**\\ └ Image resolution: **Medium** to **Hight**\\ \\ Version 10:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_021.png?direct&0x100|}} | | + | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Export PDF | **File** > **Export** > **PDF...** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128416:index_working_with_files:id1354112:file_fil_exp_pdf_op|{{:en:icon_link.png|}}]]\\ └ Source: Select sheets\\ └ Colors: **Black on white**\\ └ Size: **Original size**\\ └ Output text: **Text**\\ └ Export grid images to drawing: **Yes**\\ └ Image resolution: **Medium** to **Hight**\\ \\ Version 10:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_021.png?direct&0x100|}} | |
<WRAP noprint> | <WRAP noprint> |