This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Last revision Both sides next revision | ||
en:mdm:inputdevices:steinwald [2016/01/25 10:22] sh |
en:mdm:inputdevices:steinwald [2017/08/22 12:57] me |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | ===== Steinwald Input ===== | + | ~~NOTOC~~ |
- | The additional module is not included in the basic version of the MDM-Tool. | + | <WRAP noprint> |
- | ==== Configuration of a Steinwald-Interface-Box ==== | + | > Manual <html><b><i><font color="#E12C24">mdm - </font></i> TOOL</b></html> > Input Devices |
- | The following describes how to configure a Steinwald Interface Box as an input device. | + | </WRAP> |
+ | |||
+ | ====== Steinwald ====== | ||
+ | |||
+ | ---- | ||
+ | |||
+ | The additional module for Steinwald interface boxes is not included in the basic version of <html><b><i><font color="#E12C24">mdm - </font></i> TOOL</b></html>. | ||
+ | |||
+ | <WRAP noprint> | ||
+ | <WRAP group> | ||
+ | <WRAP column 45%> | ||
+ | //**__Inhalt__**// | ||
+ | |||
+ | • [[en:mdm:inputdevices:steinwald#Configuration of a Steinwald Interface Box]]\\ | ||
+ | • [[en:mdm:inputdevices:steinwald#Configuration of a Steinwald Measurement Device]] | ||
+ | |||
+ | \\ | ||
+ | |||
+ | </WRAP> | ||
+ | </WRAP> | ||
+ | </WRAP> | ||
+ | |||
+ | ===== Configuration of a Steinwald Interface Box ===== | ||
+ | |||
+ | The following describes how to configure a Steinwald interface box as an input device. | ||
{{:en:mdm:inputdevices:steinwald_eng_a1.png?500|}} | {{:en:mdm:inputdevices:steinwald_eng_a1.png?500|}} | ||
- | To configure the box, select it from the list with the mouse pointer. | + | To configure the interface box select it with a single mouse click from the list. |
{{:en:mdm:inputdevices:steinwald_eng_a2.png?500|}} | {{:en:mdm:inputdevices:steinwald_eng_a2.png?500|}} | ||
- | Click the **Configure** button below the list to open the configuration menu. Alternatively you can open the menu by selecting **Configure** in the context menu. | + | Click the **Configure** button below the list to open the configuration window. Alternatively you can open the context menu via a right mouse click and select the **Configure** menu entry. |
{{:en:mdm:inputdevices:steinwald_eng_a3.png?500|}} | {{:en:mdm:inputdevices:steinwald_eng_a3.png?500|}} | ||
- | In the Configuration menu you can activate or deactivate the interface box by ticking the **Enabled ** check box. | + | In the Configuration menu you can activate or deactivate the interface box by clicking the **Enabled ** check box. |
The **COM port name** drop down menu shows all active COM ports. Select the port that the interface box should connect to. If the listed COM ports are not up to date, click the **Refresh** button to update the list. | The **COM port name** drop down menu shows all active COM ports. Select the port that the interface box should connect to. If the listed COM ports are not up to date, click the **Refresh** button to update the list. | ||
Line 23: | Line 47: | ||
In the **Baud rate** drop down menu you select the baud rate of the box. | In the **Baud rate** drop down menu you select the baud rate of the box. | ||
- | When you confirm your configurations by clicking the **OK** or the **Apply** button, a corresponding number of measurement device channels is added to the list of input devices. | + | Click **Apply** to accept the settings you have made. Click **OK** to save the settings and close the Settings window. Clicking **Cancel** closes the window without saving any changes. |
- | + | ||
{{:en:mdm:inputdevices:steinwald_eng_a4.png?500|}} | {{:en:mdm:inputdevices:steinwald_eng_a4.png?500|}} | ||
- | |||
- | \\ | ||
<WRAP pagebreak></WRAP> | <WRAP pagebreak></WRAP> | ||
- | ==== Configuration of a measurement device ==== | + | ===== Configuration of a Steinwald Measurement Device ===== |
+ | This section describes how to configure a measurement device of a Steinwald interface box. | ||
{{:en:mdm:inputdevices:steinwald_eng_b1.png?500|}} | {{:en:mdm:inputdevices:steinwald_eng_b1.png?500|}} | ||
+ | |||
+ | To configure the measurement device select it with a single mouse click from the list. | ||
+ | |||
{{:en:mdm:inputdevices:steinwald_eng_b2.png?500|}} | {{:en:mdm:inputdevices:steinwald_eng_b2.png?500|}} | ||
+ | |||
+ | Click the **Configure** button below the list of devices to open the configuration window. You can also right mouse click to open the context menu and click on **Configure**. | ||
+ | |||
{{:en:mdm:inputdevices:steinwald_eng_b3.png?500|}} | {{:en:mdm:inputdevices:steinwald_eng_b3.png?500|}} | ||
+ | |||
+ | In the configuration menu you can activate or deactivate the measurement device by selecting or deselecting the **Enable** check box. | ||
+ | |||
+ | You can enter a name for the devicein the **Name** field. This is then displayed in the list. This makes identification easier if there are more than one device in the list. | ||
+ | |||
+ | The device's **Serial number** and **Type** are also displayed. These settings cannot be changed. | ||
+ | |||
{{:en:mdm:inputdevices:steinwald_eng_b4.png?500|}} | {{:en:mdm:inputdevices:steinwald_eng_b4.png?500|}} | ||
+ | In the **Feedback** menu select the output device from which you expect acknowledgement of receipt for measurement data. If you select the **Green LED** from the list, this LED on the transmitter will light up when a measurement value has been processed. Selecting **Virtual COM Port** or **Virtual Keyboard** from the list results in this device taking on the acknowledgement of receipt and the corresponding LEDs light up. | ||
+ | |||
+ | Click **Apply** to adopt the settings you have chosen. Clicking **OK** saves the data and closes the Settings window. Clicking **Cancel** closes the window without saving any changes. | ||
+ | |||
+ | <WRAP noprint> | ||
+ | |||
+ | ---- | ||
+ | |||
+ | <WRAP group> | ||
+ | <WRAP col2> | ||
+ | |||
+ | <WRAP rightalign> | ||
+ | **Back to**\\ | ||
+ | Input Devices > [[en:mdm:inputdevices:mux|MUX-Protokoll]] | ||
+ | </WRAP> | ||
+ | |||
+ | **Continue with**\\ | ||
+ | Input Devices > [[en:mdm:inputdevices:sylvac|Sylvac Bluetooth]] | ||
+ | |||
+ | </WRAP> | ||
+ | </WRAP> | ||
+ | |||
+ | </WRAP> |