User Tools

Site Tools


en:infra-convert:user:config:features

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
en:infra-convert:user:config:features [2019/08/09 11:17]
me
en:infra-convert:user:config:features [2019/08/09 11:24]
me
Line 134: Line 134:
 ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Ignore added entry “min./​max.” | Stipulates that the added entry “min.” or “max.” is ignored and the value entered is interpreted as generally toleranced nominal value. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  | ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Ignore added entry “min./​max.” | Stipulates that the added entry “min.” or “max.” is ignored and the value entered is interpreted as generally toleranced nominal value. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  |
 ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen.png?​nolink&​0x50 |}}  ^ Do not apply zero values in characteristic | Stipulates that the zero values mentioned above are not applied in the “nominal value”, “upper tolerance” or “lower tolerance” fields. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen_1.png?​nolink&​0x50 |}}  | ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen.png?​nolink&​0x50 |}}  ^ Do not apply zero values in characteristic | Stipulates that the zero values mentioned above are not applied in the “nominal value”, “upper tolerance” or “lower tolerance” fields. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen_1.png?​nolink&​0x50 |}}  |
 +
 +Possible settings based on an example, default setting highlighted in gray:
 +
 +{{ :​en:​infra-convert:​user:​settings:​einstellungen_grenzmasse_in_eine_richtung.png?​nolink&​600 |}}
  
 > Up to the program version mentioned above: > Up to the program version mentioned above:
Line 210: Line 214:
 ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Nominal dimension = width of the tolerance zone; upper tol. = width of the tolerance zone; lower tol. = 0 | Specifies that the width of the tolerance zone during stamping is interpreted as the nominal dimension and as the upper tolerance value. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  | ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Nominal dimension = width of the tolerance zone; upper tol. = width of the tolerance zone; lower tol. = 0 | Specifies that the width of the tolerance zone during stamping is interpreted as the nominal dimension and as the upper tolerance value. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  |
 ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen.png?​nolink&​0x50 |}}  ^ Zero values are not applied in the characteristic | Specifies that the zero values named above are not applied in the "​Nominal dimension",​ "Upper tolerance"​ / "Lower tolerance"​ fields. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen_0.png?​nolink&​0x50 |}}  | ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen.png?​nolink&​0x50 |}}  ^ Zero values are not applied in the characteristic | Specifies that the zero values named above are not applied in the "​Nominal dimension",​ "Upper tolerance"​ / "Lower tolerance"​ fields. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen_0.png?​nolink&​0x50 |}}  |
 +
 +Possible settings based on an example, default setting highlighted in gray:
 +
 +{{ :​en:​infra-convert:​user:​settings:​einstellungen_form_und_lage.png?​nolink&​600 |}}
  
 \\  \\ 
Line 253: Line 261:
 ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Nominal dimension = limit value; upper tol. = limit value; lower tol. = 0 | Specifies that the limit value from the surface specification in the characteristic is set as the nominal dimension and upper tolerance limit. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  | ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Nominal dimension = limit value; upper tol. = limit value; lower tol. = 0 | Specifies that the limit value from the surface specification in the characteristic is set as the nominal dimension and upper tolerance limit. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  |
 ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen.png?​nolink&​0x50 |}}  ^ Zero values are not applied in the characteristic | Specifies that the zero values named above are not applied in the "​Nominal dimension",​ "Upper tolerance"​ and "Lower tolerance"​ fields. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen_1.png?​nolink&​0x50 |}}  | ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen.png?​nolink&​0x50 |}}  ^ Zero values are not applied in the characteristic | Specifies that the zero values named above are not applied in the "​Nominal dimension",​ "Upper tolerance"​ and "Lower tolerance"​ fields. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen_1.png?​nolink&​0x50 |}}  |
 +
 +Possible settings based on an example, default setting highlighted in gray:
 +
 +{{ :​en:​infra-convert:​user:​settings:​einstellungen_oberflaechen.png?​nolink&​600 |}}
  
 \\  \\ 
en/infra-convert/user/config/features.txt · Last modified: 2024/02/27 08:24 by me