This shows you the differences between two versions of the page.
Both sides previous revision Previous revision | Next revision Both sides next revision | ||
en:infra-convert:user:config:features [2019/08/09 11:17] me |
en:infra-convert:user:config:features [2019/08/09 11:24] me |
||
---|---|---|---|
Line 134: | Line 134: | ||
^ {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld.png?nolink&0x50 |}} ^ Ignore added entry “min./max.” | Stipulates that the added entry “min.” or “max.” is ignored and the value entered is interpreted as generally toleranced nominal value. | {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld_0.png?nolink&0x50 |}} | | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld.png?nolink&0x50 |}} ^ Ignore added entry “min./max.” | Stipulates that the added entry “min.” or “max.” is ignored and the value entered is interpreted as generally toleranced nominal value. | {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld_0.png?nolink&0x50 |}} | | ||
^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Do not apply zero values in characteristic | Stipulates that the zero values mentioned above are not applied in the “nominal value”, “upper tolerance” or “lower tolerance” fields. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_1.png?nolink&0x50 |}} | | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Do not apply zero values in characteristic | Stipulates that the zero values mentioned above are not applied in the “nominal value”, “upper tolerance” or “lower tolerance” fields. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_1.png?nolink&0x50 |}} | | ||
+ | |||
+ | Possible settings based on an example, default setting highlighted in gray: | ||
+ | |||
+ | {{ :en:infra-convert:user:settings:einstellungen_grenzmasse_in_eine_richtung.png?nolink&600 |}} | ||
> Up to the program version mentioned above: | > Up to the program version mentioned above: | ||
Line 210: | Line 214: | ||
^ {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld.png?nolink&0x50 |}} ^ Nominal dimension = width of the tolerance zone; upper tol. = width of the tolerance zone; lower tol. = 0 | Specifies that the width of the tolerance zone during stamping is interpreted as the nominal dimension and as the upper tolerance value. | {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld_0.png?nolink&0x50 |}} | | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld.png?nolink&0x50 |}} ^ Nominal dimension = width of the tolerance zone; upper tol. = width of the tolerance zone; lower tol. = 0 | Specifies that the width of the tolerance zone during stamping is interpreted as the nominal dimension and as the upper tolerance value. | {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld_0.png?nolink&0x50 |}} | | ||
^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Zero values are not applied in the characteristic | Specifies that the zero values named above are not applied in the "Nominal dimension", "Upper tolerance" / "Lower tolerance" fields. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_0.png?nolink&0x50 |}} | | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Zero values are not applied in the characteristic | Specifies that the zero values named above are not applied in the "Nominal dimension", "Upper tolerance" / "Lower tolerance" fields. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_0.png?nolink&0x50 |}} | | ||
+ | |||
+ | Possible settings based on an example, default setting highlighted in gray: | ||
+ | |||
+ | {{ :en:infra-convert:user:settings:einstellungen_form_und_lage.png?nolink&600 |}} | ||
\\ | \\ | ||
Line 253: | Line 261: | ||
^ {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld.png?nolink&0x50 |}} ^ Nominal dimension = limit value; upper tol. = limit value; lower tol. = 0 | Specifies that the limit value from the surface specification in the characteristic is set as the nominal dimension and upper tolerance limit. | {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld_0.png?nolink&0x50 |}} | | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld.png?nolink&0x50 |}} ^ Nominal dimension = limit value; upper tol. = limit value; lower tol. = 0 | Specifies that the limit value from the surface specification in the characteristic is set as the nominal dimension and upper tolerance limit. | {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld_0.png?nolink&0x50 |}} | | ||
^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Zero values are not applied in the characteristic | Specifies that the zero values named above are not applied in the "Nominal dimension", "Upper tolerance" and "Lower tolerance" fields. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_1.png?nolink&0x50 |}} | | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Zero values are not applied in the characteristic | Specifies that the zero values named above are not applied in the "Nominal dimension", "Upper tolerance" and "Lower tolerance" fields. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_1.png?nolink&0x50 |}} | | ||
+ | |||
+ | Possible settings based on an example, default setting highlighted in gray: | ||
+ | |||
+ | {{ :en:infra-convert:user:settings:einstellungen_oberflaechen.png?nolink&600 |}} | ||
\\ | \\ |