This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
en:infra-convert:user:config:features [2023/07/23 12:34] me [Characteristic] |
en:infra-convert:user:config:features [2024/02/27 08:24] (current) me [“Shape and positional tolerances” group] |
||
---|---|---|---|
Line 132: | Line 132: | ||
==== “Number format” group ==== | ==== “Number format” group ==== | ||
- | |||
- | **Note** Available from program version 2.2.8. | ||
|< 100% 8% 22% 55% 15%>| | |< 100% 8% 22% 55% 15%>| | ||
Line 139: | Line 137: | ||
^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Create numerical values with at least ... | When creating a characteristic (read in or calculate), the numerical values for the nominal dimension, the upper tolerance and the lower tolerance are created with a minimum number of n decimal places. This means missing digits up to the specified number are filled with zeros, example: "1.5" ⇒ "1.500". The number of places after the decimal point is not exceeded, example: "0.3333" ⇒ "0.3333". | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_0.png?nolink&0x50 |}} | | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Create numerical values with at least ... | When creating a characteristic (read in or calculate), the numerical values for the nominal dimension, the upper tolerance and the lower tolerance are created with a minimum number of n decimal places. This means missing digits up to the specified number are filled with zeros, example: "1.5" ⇒ "1.500". The number of places after the decimal point is not exceeded, example: "0.3333" ⇒ "0.3333". | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_0.png?nolink&0x50 |}} | | ||
^ {{ :en:infra-convert:user:functions:icon_steuerelement_zaehlfeld.png?nolink&0x50 |}} ^ ... decimal places. | ::: | 3 | | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_zaehlfeld.png?nolink&0x50 |}} ^ ... decimal places. | ::: | 3 | | ||
+ | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Convert angles to decimal values on creation | Specifies that numerical values read in the sixty system are converted to decimal values when stamping. Example: 1°30' → 1.5°.\\ **Note** Available from program version 4.3.0. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_0.png?nolink&0x50 |}} | | ||
\\ | \\ | ||
Line 171: | Line 170: | ||
^ {{ :en:infra-convert:user:functions:icon_steuerelement_dropdown-listenfeld.png?nolink&0x50 |}} ^ Auxiliary dimensions | Defines when and if auxiliary dimensions are to be created:\\ • Create only for single stamping\\ • Always create\\ • Never create\\ | Create only for single stamping | | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_dropdown-listenfeld.png?nolink&0x50 |}} ^ Auxiliary dimensions | Defines when and if auxiliary dimensions are to be created:\\ • Create only for single stamping\\ • Always create\\ • Never create\\ | Create only for single stamping | | ||
^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Auxiliary dimensions: Use tolerance tables | Specifies that auxiliary dimensions are generally tolerated. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_0.png?nolink&0x50 |}} | | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Auxiliary dimensions: Use tolerance tables | Specifies that auxiliary dimensions are generally tolerated. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_0.png?nolink&0x50 |}} | | ||
- | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_dropdown-listenfeld.png?nolink&0x50 |}} ^ Theoretically accurate dimensions | Specifies when and if theoretically accurate measurements are to be created:\\ • Create only for single stamping\\ • Always create\\ • Never create\\ | Create only for single stamping | | + | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_dropdown-listenfeld.png?nolink&0x50 |}} ^ Theoretically exact dimensions | Specifies when and if theoretically exact measurements are to be created:\\ • Create only for single stamping\\ • Always create\\ • Never create\\ | Create only for single stamping | |
- | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Auxiliary dimensions: Use tolerance tables | Specifies that theoretically accurate dimensions are generally tolerated. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_0.png?nolink&0x50 |}} | | + | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Theoretically exact dimensions: Use tolerance tables | Specifies that theoretically exact dimensions are generally tolerated. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_0.png?nolink&0x50 |}} | |
- | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_dropdown-listenfeld.png?nolink&0x50 |}} ^ Dimensions without tolerance entry at nominal dimension | Defines when and whether dimensions are to be created without tolerance entry at the nominal dimension:\\ • Create only for single stamping\\ • Always create\\ • Never create\\ | Always create | | + | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_dropdown-listenfeld.png?nolink&0x50 |}} ^ Rough dimensions | Specifies when and if rough dimensions are to be created:\\ • Create only for single stamping\\ • Always create\\ • Never create\\ \\ **Note** Available from program version 4.3.0. | Always create | |
+ | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Rough dimensions: Use tolerance tables | Specifies that theoretically exact dimensions are generally tolerated.\\ \\ **Note** Available from program version 4.3.0. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_1.png?nolink&0x50 |}} | | ||
+ | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_dropdown-listenfeld.png?nolink&0x50 |}} ^ Control dimensions | Specifies when and if control dimensions are to be created:\\ • Create only for single stamping\\ • Always create\\ • Never create\\ \\ **Note** Available from program version 4.3.0. | Always create | | ||
+ | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_dropdown-listenfeld.png?nolink&0x50 |}} ^ Dimensions without tolerance entry at nominal dimension | Defines when and whether dimensions are to be created without tolerance entry at the nominal dimension:\\ • Create only for single stamping\\ • Always create\\ • Never create | Always create | | ||
^ {{ :en:infra-convert:user:functions:icon_steuerelement_dropdown-listenfeld.png?nolink&0x50 |}} ^ Other variable characteristics | Defines when and if other variable characteristics are to be created:\\ • Create only for single stamping\\ • Always create\\ • Never create\\ | Always create | | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_dropdown-listenfeld.png?nolink&0x50 |}} ^ Other variable characteristics | Defines when and if other variable characteristics are to be created:\\ • Create only for single stamping\\ • Always create\\ • Never create\\ | Always create | | ||
^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Not indicated limit = 0 | Defines that the tolerance value 0 is set when creating a characteristic if the limit deviation is not specified in the drawing entry. Example: For **10 +0.1**, **0.0** is set for the lower tolerance.\\ \\ **Note** Available from program version 4.1.9. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_0.png?nolink&0x50 |}} | | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Not indicated limit = 0 | Defines that the tolerance value 0 is set when creating a characteristic if the limit deviation is not specified in the drawing entry. Example: For **10 +0.1**, **0.0** is set for the lower tolerance.\\ \\ **Note** Available from program version 4.1.9. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_0.png?nolink&0x50 |}} | | ||
Line 291: | Line 293: | ||
^ {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld.png?nolink&0x50 |}} ^ Nominal dimension = 0; upper tol. = width of the tolerance zone; lower tol. = 0 | Specifies that the width of the tolerance zone is interpreted as the upper tolerance value during stamping. | {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld_1.png?nolink&0x50 |}} | | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld.png?nolink&0x50 |}} ^ Nominal dimension = 0; upper tol. = width of the tolerance zone; lower tol. = 0 | Specifies that the width of the tolerance zone is interpreted as the upper tolerance value during stamping. | {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld_1.png?nolink&0x50 |}} | | ||
^ {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld.png?nolink&0x50 |}} ^ Nominal dimension = width of the tolerance zone; upper tol. = width of the tolerance zone; lower tol. = 0 | Specifies that the width of the tolerance zone during stamping is interpreted as the nominal dimension and as the upper tolerance value. | {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld_0.png?nolink&0x50 |}} | | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld.png?nolink&0x50 |}} ^ Nominal dimension = width of the tolerance zone; upper tol. = width of the tolerance zone; lower tol. = 0 | Specifies that the width of the tolerance zone during stamping is interpreted as the nominal dimension and as the upper tolerance value. | {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld_0.png?nolink&0x50 |}} | | ||
+ | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_optionsfeld.png?nolink&0x50 |}} ^ Nominal dimension = 0; upper tol. = (0,5) × width of the tolerance zone; lower tol. = (-0,5) × width of the tolerance zone | Specifies that the width of the tolerance zone is interpreted symmetrically divided as upper and lower tolerance value when stamping.\\ \\ **Note** Available from program version 4.4.5. | {{ :de:infra-convert:user:functions:icon_steuerelement_optionsfeld_0.png?nolink&0x50 |}} | | ||
^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Zero values are not applied in the characteristic | Specifies that the zero values named above are not applied in the "Nominal dimension", "Upper tolerance" / "Lower tolerance" fields. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_0.png?nolink&0x50 |}} | | ^ {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen.png?nolink&0x50 |}} ^ Zero values are not applied in the characteristic | Specifies that the zero values named above are not applied in the "Nominal dimension", "Upper tolerance" / "Lower tolerance" fields. | {{ :en:infra-convert:user:functions:icon_steuerelement_kontrollkaestchen_0.png?nolink&0x50 |}} | | ||