User Tools

Site Tools


en:infra-convert:user:terms

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
en:infra-convert:user:terms [2021/02/22 14:14]
me [Drawing data format: PDF]
en:infra-convert:user:terms [2023/10/20 16:02] (current)
me [Antialiasing]
Line 6: Line 6:
 </​WRAP>​ </​WRAP>​
  
-====== Terms ======+<WRAP group> 
 +<WRAP column 3.5%> 
 +{{:​en:​icon_terms.png?​nolink&​30}} 
 +</​WRAP>​ 
 +<WRAP column 91.5%> 
 +<​html><​b><​font size="​+2">​Terms</​font></​b></​html>​ 
 +</​WRAP>​ 
 +</​WRAP>​
  
 ---- ----
  
 Important terms are explained in the following. Important terms are explained in the following.
 +
 +\\ 
  
 <WRAP noprint> <WRAP noprint>
Line 62: Line 71:
 <WRAP column 60%> <WRAP column 60%>
  
-The right graph shows graphic exports from #@IC_HTML@# using the possible supersampling methods and with different quality levels (size of the original: 100 mm; exported as PNG with 300 dpi) Runtime and memory usage increase with the quality level and complexity of the algorithm from "​average"​ to "​Lanczos 3".+The right graph shows graphic exports from #@IC_HTML@# using the possible supersampling methods ​(software rendering) ​and with different quality levels (size of the original: 100 mm; exported as PNG with 300 dpi) Runtime and memory usage increase with the quality level and complexity of the algorithm from "​average"​ to "​Lanczos 3".
  
 </​WRAP>​ </​WRAP>​
Line 103: Line 112:
 ^ Standard characteristic | Characteristic that is not assigned to any of the following categories. | – | ^ Standard characteristic | Characteristic that is not assigned to any of the following categories. | – |
 ^ Special characteristic | A critical characteristic that deserves special attention. If the implementation of the characteristic does not correspond to the drawing specifications,​ a potential risk to functions (operational safety, interchangeability,​ service life, etc.) has to be expected to a great extent.\\ \\ Example of tagging:\\ {{ :​en:​infra-convert:​user:​terms:​grafik_besondere_merkmale.png?​nolink&​420| }} | – | ^ Special characteristic | A critical characteristic that deserves special attention. If the implementation of the characteristic does not correspond to the drawing specifications,​ a potential risk to functions (operational safety, interchangeability,​ service life, etc.) has to be expected to a great extent.\\ \\ Example of tagging:\\ {{ :​en:​infra-convert:​user:​terms:​grafik_besondere_merkmale.png?​nolink&​420| }} | – |
-^ Auxiliary measurement | Measurement that is not required for the geometric determination of a part and is not considered an integral part of the contract.\\ \\ Example for the tagging:\\ {{ :​en:​infra-convert:​user:​terms:​grafik_hilfsmasse.png?​nolink&​420| }} | • DIN 406-10:1992-12 +^ Auxiliary measurement | Measurement that is not required for the geometric determination of a part and is not considered an integral part of the contract.\\ \\ Example for the tagging:\\ {{ :​en:​infra-convert:​user:​terms:​grafik_hilfsmasse.png?​nolink&​420| }} | • DIN EN ISO 129-
-^ Rough measurement | Measurement that refers to the initial state of an object.\\ \\ Example for the tagging:\\ {{ :​en:​infra-convert:​user:​terms:​grafik_rohmasse.png?​nolink&​420| }} | • DIN 406-10:​1992-12 ​+^ Rough measurement | Measurement that refers to the initial state of an object.\\ \\ Example for the tagging:\\ {{ :​en:​infra-convert:​user:​terms:​grafik_rohmasse.png?​nolink&​420| }} | • DIN 406-10 | 
-^ Theoretically accurate measurement | Measurement for indication of the geometrically ideal (theoretically precise) position or shape of the dimensioned shape element.\\ \\ Example for the tagging:\\ {{ :​en:​infra-convert:​user:​terms:​grafik_theoretisch_genaue_masse.png?​nolink&​420| }} | • DIN 406-10:1992-12 +^ Theoretically accurate measurement | Measurement for indication of the geometrically ideal (theoretically precise) position or shape of the dimensioned shape element.\\ \\ Example for the tagging:\\ {{ :​en:​infra-convert:​user:​terms:​grafik_theoretisch_genaue_masse.png?​nolink&​420| }} | • DIN EN ISO 129-
-^ Test measurement | Measurement that must be given special attention when determining the extent of the test / test accuracy.\\ \\ Example for the tagging:\\ {{ :​en:​infra-convert:​user:​terms:​grafik_pruefmasse.png?​nolink&​420| }} | • DIN 406-10:​1992-12 ​|+^ Test measurement | Measurement that must be given special attention when determining the extent of the test / test accuracy.\\ \\ Example for the tagging:\\ {{ :​en:​infra-convert:​user:​terms:​grafik_pruefmasse.png?​nolink&​420| }} | • DIN 406-10 |
  
 \\  \\ 
Line 489: Line 498:
 The PDF format (PDF = "​Portable Document Format"​) supports raster-based and vector-based data storage. Coded text characters are stored in text fields, such as "⌀ 20" in the adjacent example. The PDF format (PDF = "​Portable Document Format"​) supports raster-based and vector-based data storage. Coded text characters are stored in text fields, such as "⌀ 20" in the adjacent example.
  
-> In #​@IC_HTML@#,​ drawings in raster-based PDF format can be stamped manually using the quick input dialog. ​Drawings in vector-based ​PDF format ​can be stamped automatically* if the characters are coded.\\ \\ * A pro license is required.\\ \\ **See**\\ Functions > Characteristics > [[en:​infra-convert:​user:​functions:​ballooning_man|Manually stamp]]\\ Functions > Characteristics > [[en:​infra-convert:​user:​functions:​ballooning|Automatic stamping]]+> In #​@IC_HTML@#,​ drawings in raster-based PDF format can be stamped manually using the quick input dialog. PDF drawing files can be stamped automatically*if the characters are encoded.\\ \\ * A pro license is required.\\ \\ **See**\\ Functions > Characteristics > [[en:​infra-convert:​user:​functions:​ballooning_man|Manually stamp]]\\ Functions > Characteristics > [[en:​infra-convert:​user:​functions:​ballooning|Automatic stamping]]
  
 </​WRAP>​ </​WRAP>​
Line 673: Line 682:
 ^ ::: ^ Pound-force-inch*² | lbf-i | – | PoundForceInch | ^ ::: ^ Pound-force-inch*² | lbf-i | – | PoundForceInch |
 ^ ::: ^ Pound-force-foot*² | lbf-ft | – | PoundForceFoot | ^ ::: ^ Pound-force-foot*² | lbf-ft | – | PoundForceFoot |
-^ Effort ^ Milliwatt*³ | mW | DIN 1301-1:​2010-10 | MilliWatt ​|+^ Effort ^ Milliwatt*³ | mW | DIN 1301-1:​2010-10 | Milliwatt ​|
 ^ ::: ^ Watt*³ | W | DIN 1301-1:​2010-10 | Watt | ^ ::: ^ Watt*³ | W | DIN 1301-1:​2010-10 | Watt |
-^ ::: ^ Kilowatt*³ | kW | DIN 1301-1:​2010-10 | KiloWatt ​|+^ ::: ^ Kilowatt*³ | kW | DIN 1301-1:​2010-10 | Kilowatt ​|
 ^ Temperature ^ Degrees Celsius | °C | DIN 1301-1:​2010-10 | Celsius | ^ Temperature ^ Degrees Celsius | °C | DIN 1301-1:​2010-10 | Celsius |
 ^ ::: ^ Degrees Fahrenheit | °F | [NIST-19] | Fahrenheit | ^ ::: ^ Degrees Fahrenheit | °F | [NIST-19] | Fahrenheit |
Line 681: Line 690:
 ^ Electricity ^ Volt*³ | V | DIN 1301-1:​2010-10 | Volt | ^ Electricity ^ Volt*³ | V | DIN 1301-1:​2010-10 | Volt |
 ^ ::: ^ Ampere*³ | A | DIN 1301-1:​2010-10 | Ampere | ^ ::: ^ Ampere*³ | A | DIN 1301-1:​2010-10 | Ampere |
 +^ ::: ^ Nanoampere*⁶ | nA | DIN 1301-1:​2010-10 | NanoAmpere |
 +^ ::: ^ Microampere*⁶ | µA | DIN 1301-1:​2010-10 | MicroAmpere |
 +^ ::: ^ Milliampere*⁶ | mA | DIN 1301-1:​2010-10 | MilliAmpere |
 +^ ::: ^ Kiloampere*⁶ | kA | DIN 1301-1:​2010-10 | KiloAmpere |
 +^ ::: ^ Megaampere*⁶ | MA | DIN 1301-1:​2010-10 | MegaAmpere |
 +^ ::: ^ Gigaampere*⁶ | GA | DIN 1301-1:​2010-10 | GigaAmpere |
 ^ ::: ^ Ohm*³ | Ω | DIN 1301-1:​2010-10 | Ohm | ^ ::: ^ Ohm*³ | Ω | DIN 1301-1:​2010-10 | Ohm |
-^ ::: ^ Ampere per centimeter*⁴ | A/cm | | AmperePerCentimeter | +^ ::: ^ Nanoohm*⁶ | nΩ | DIN 1301-1:​2010-10 | NanoOhm | 
-^ ::: ^ Ampere per meter*⁴ | A/m | | AmperePerMeter | +^ ::: ^ Microohm*⁶ | µΩ | DIN 1301-1:​2010-10 | MicroOhm | 
-^ ::: ^ Millitesla*⁴ | mT | | MilliTesla |+^ ::: ^ Milliohm*⁶ | mΩ | DIN 1301-1:​2010-10 | MilliOhm | 
 +^ ::: ^ Kiloohm*⁶ | kΩ | DIN 1301-1:​2010-10 | KiloOhm | 
 +^ ::: ^ Megaohm*⁶ | MΩ | DIN 1301-1:​2010-10 | MegaOhm | 
 +^ ::: ^ Gigaohm*⁶ | GΩ | DIN 1301-1:​2010-10 | GigaOhm | 
 +^ ::: ^ Ampere per centimeter*⁴ | A/cm | – | AmperePerCentimeter | 
 +^ ::: ^ Ampere per meter*⁴ | A/m | – | AmperePerMeter | 
 +^ ::: ^ Millitesla*⁴ | mT | – | MilliTesla |
 ^ ::: ^ Tesla*⁴ | T | - | Tesla | ^ ::: ^ Tesla*⁴ | T | - | Tesla |
 +^ ::: ^ Volt*³ | V | DIN 1301-1:​2010-10 | Volt |
 +^ ::: ^ Nanovolt*⁶ | nV | DIN 1301-1:​2010-10 | NanoVolt |
 +^ ::: ^ Microvolt*⁶ | µV | DIN 1301-1:​2010-10 | MicroVolt |
 +^ ::: ^ Millivolt*⁶ | mV | DIN 1301-1:​2010-10 | MilliVolt |
 +^ ::: ^ Kilovolt*⁶ | kV | DIN 1301-1:​2010-10 | KiloVolt |
 +^ ::: ^ Megavolt*⁶ | MV | DIN 1301-1:​2010-10 | MegaVolt |
 +^ ::: ^ Gigavolt*⁶ | GV | DIN 1301-1:​2010-10 | GigaVolt |
 +^ Sound ^ Phon*⁵ | phon | – | Phon |
 +^ ::: ^ Sone*⁵ | sone | – | Sone |
 ^ Level ^ Decibel*³ | dB | DIN 5493:​2013-10 | Decibel | ^ Level ^ Decibel*³ | dB | DIN 5493:​2013-10 | Decibel |
 ^ Auxiliary units ^ Number (of pieces)*³ | pcs = Stk. | – | Piece | ^ Auxiliary units ^ Number (of pieces)*³ | pcs = Stk. | – | Piece |
Line 691: Line 721:
 ^ ::: ^ Percent*¹ | % | DIN 5466:​1983-02 | Percent | ^ ::: ^ Percent*¹ | % | DIN 5466:​1983-02 | Percent |
 ^ ::: ^ Mol*³ | mol | DIN 1301-1:​2010-10 | Mol | ^ ::: ^ Mol*³ | mol | DIN 1301-1:​2010-10 | Mol |
-| NIST-19: National Institute of Standards and Technology, Gaithersburg,​ Maryland, USA: NIST Handbook 44 : Specifications,​ Tolerances, and Other Technical Requirements for Weighing and Measuring Devices (Appendix C. General Tables of Units of Measurement) 2019.\\ *¹ Available from program version 1.2.0.23\\ *² Available from program version 1.3.9.5\\ *³ Available from program version 1.3.9.8\\ *⁴ Available from program version 2.1.1 |||||+| NIST-19: National Institute of Standards and Technology, Gaithersburg,​ Maryland, USA: NIST Handbook 44 : Specifications,​ Tolerances, and Other Technical Requirements for Weighing and Measuring Devices (Appendix C. General Tables of Units of Measurement) 2019.\\ *¹ Available from program version 1.2.0.23\\ *² Available from program version 1.3.9.5\\ *³ Available from program version 1.3.9.8\\ *⁴ Available from program version 2.1.1\\ *⁵ Available from program version 2.10.0\\ *⁶ Available from program version 4.2.0 |||||
  
 \\  \\ 
Line 813: Line 843:
 </​WRAP>​ </​WRAP>​
 <WRAP column half> <WRAP column half>
-{{ :​en:​infra-convert:​user:​terms:​mehrfachmerkmale_dupliziert.png?​nolink&​800 |}}+{{ :​en:​infra-convert:​user:​terms:​mehrfachmerkmale_erneut_gestempelt.png?​nolink&​800 |}}
 </​WRAP>​ </​WRAP>​
 </​WRAP>​ </​WRAP>​
Line 1070: Line 1100:
 <WRAP rightalign>​ <WRAP rightalign>​
 **Go to previous page**\\ ​ **Go to previous page**\\ ​
-More > [[en:​infra-convert:​user:​collectdrw|Create test plans from a collective ​drawing]]+More > [[en:​infra-convert:​user:​ic_cec_cal|From the drawing ​to the measuring program in ZEISS CALYPSO]]
 </​WRAP>​ </​WRAP>​
  
-\\ +**Go to next page**\\  
 +More > [[en:​infra-convert:​faq|Frequently asked questions and answers]]
 \\  \\ 
  
en/infra-convert/user/terms.1613999648.txt.gz · Last modified: 2021/02/22 14:14 by me