User Tools

Site Tools


en:infra-convert:user:config:features

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
en:infra-convert:user:config:features [2019/01/10 08:46]
me [“Limit values in one direction (min., max.)” group]
en:infra-convert:user:config:features [2019/10/08 16:38]
me [Characteristic]
Line 31: Line 31:
  • [[en:​infra-convert:​user:​config:​features#"​General characteristic settings"​ group]]\\ ​  • [[en:​infra-convert:​user:​config:​features#"​General characteristic settings"​ group]]\\ ​
  • [[en:​infra-convert:​user:​config:​features#"​Format characteristic title" group]]\\ ​  • [[en:​infra-convert:​user:​config:​features#"​Format characteristic title" group]]\\ ​
 + • [[en:​infra-convert:​user:​config:​features#"​Numerical precision"​ group]]\\ ​
  • [[en:​infra-convert:​user:​config:​features#​“Attributive characteristic” group]]\\ ​  • [[en:​infra-convert:​user:​config:​features#​“Attributive characteristic” group]]\\ ​
  • [[en:​infra-convert:​user:​config:​features#​“Word specifications” group]]\\ ​  • [[en:​infra-convert:​user:​config:​features#​“Word specifications” group]]\\ ​
Line 45: Line 46:
  • [[en:​infra-convert:​user:​config:​features#​“Edges with indeterminate shape” group]]\\ ​  • [[en:​infra-convert:​user:​config:​features#​“Edges with indeterminate shape” group]]\\ ​
  • [[en:​infra-convert:​user:​config:​features#​“Surface parameters” group]]\\ ​  • [[en:​infra-convert:​user:​config:​features#​“Surface parameters” group]]\\ ​
- • [[en:​infra-convert:​user:​config:​features#​“Simplified ​surface specifications” group]]+ • [[en:​infra-convert:​user:​config:​features#​“Simplified ​indications” group]]
  
 \\  \\ 
Line 80: Line 81:
  
 ==== “Format characteristic title” group ==== ==== “Format characteristic title” group ====
 +
 +\\ 
  
 |< 100% 8% 22% 55% 15%>​| ​ |< 100% 8% 22% 55% 15%>​| ​
 ^  Option ​ ^^  Function ​ ^  Default setting ​ ^ ^  Option ​ ^^  Function ​ ^  Default setting ​ ^
-^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_eingabefeld.png?​nolink&​0x50 |}}  ^ Format characteristic title | Specifies how the characteristic title is formed. The variable letters are placed in angle brackets. Separators and order can be freely selected. Variables: CL Characteristic classCLSY Symbol / label of the classNominal ​dimensions; ​UT Upper toleranceLT Lower tolerance; ​Tolerance class / fitUpper or lower limit dimension ("min./max.")CommentCON = Condition"|  {CL} {CLSY} {N}  |+^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_eingabefeld.png?​nolink&​0x50 |}}  ^ Variable Characteristics ​| Specifies how the characteristic title is formed. The variable letters are placed in angle brackets. Separators and order can be freely selected. Variables:\\ **CL** Characteristic class ("​__cl__ass"​)\\ **CLSY** Symbol / label of the class ("​__cl__ass __sy__mbol"​)\\ **N** Nominal ​size ("​__n__ominal size"​)\\ **UT** Upper tolerance ​("​__u__pper __t__olerance"​)\\ **LT** Lower Tolerance ("​__l__ower __t__olerance"​)\\ **F** Tolerance class / fit ("​__f__it"​)\\ **M** Upper or lower limit dimension ("__m__in./__m__ax.")\\ **C** Comment ​("​__c__omment"​)\\ **CON** Modifiers ("__con__dition"​) ​|  {CL} {CLSY} {N}  | 
 +^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_eingabefeld.png?​nolink&​0x50 |}}  ^ Attributive Characteristics | Specifies how the characteristic title is formed. The variable letters are placed in angle brackets. Separators and order can be freely selected. Variables:​\\ **CL** Characteristic class ("​__cl__ass"​)\\ **CLSY** Symbol / label of the class ("​__cl__ass __sy__mbol"​)\\ **N** Nominal size ("​__n__ominal size"​)\\ **UT** Upper tolerance ("​__u__pper __t__olerance"​)\\ **LT** Lower Tolerance ("​__l__ower __t__olerance"​)\\ **F** Tolerance class / fit ("​__f__it"​)\\ **M** Upper or lower limit dimension ("​__m__in./​__m__ax."​)\\ **C** Comment ("​__c__omment"​)\\ **CON** Modifiers ("​__con__dition"​)\\ \\ **Note** Available from program version 1.3.1.7. |  {CL} {TXT}  |
  
 \\  \\ 
 +
 +==== “Numerical precision” group ====
 +
 +**Note** Available from program version 1.3.9.9.
 +
 +|< 100% 8% 22% 55% 15%>​| ​
 +^  Option ​ ^^  Function ​ ^  Default setting ​ ^
 +^ Converted results (Degree, Minute, Second to decimal) and calculations (Tolerance value as a fraction of the nominal value) are rounded to ||||
 +^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_zaehlfeld.png?​nolink&​0x50 |}}  ^ ... significant digits | Number of significant digits if the first significant digit is not '​1'​.\\ \\ **See also** More > Terms > [[en:​infra-convert:​user:​terms#​numerical_precision|Numerical precision]] |  3  |
 +^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_zaehlfeld.png?​nolink&​0x50 |}}  ^ ... significant digits if the first relevant digit is a '​1'​. | Number of significant digits if the first significant digit is '​1'​.\\ \\ **See also** More > Terms > [[en:​infra-convert:​user:​terms#​numerical_precision|Numerical precision]] |  4  |
 +
 +\\ 
 +
  
 ==== “Attributive characteristic” group ==== ==== “Attributive characteristic” group ====
Line 128: Line 145:
 ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Create limit value as nominal value | Stipulates that the value entered is interpreted as untoleranced nominal value. Upper and lower tolerances are given zero values. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  | ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Create limit value as nominal value | Stipulates that the value entered is interpreted as untoleranced nominal value. Upper and lower tolerances are given zero values. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  |
 ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Create nominal value with upper and lower tolerances | Stipulates that the value entered is interpreted unilaterally as generally toleranced nominal value (with added entry '​min.':​ upper tolerance = tolerance value; with added entry '​max.':​ lower tolerance = tolerance value). In each case the remaining tolerance is given a value of zero. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  | ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Create nominal value with upper and lower tolerances | Stipulates that the value entered is interpreted unilaterally as generally toleranced nominal value (with added entry '​min.':​ upper tolerance = tolerance value; with added entry '​max.':​ lower tolerance = tolerance value). In each case the remaining tolerance is given a value of zero. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  |
-^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Create ​nonimal ​value and limit value as tolerances | Stipulates that the value entered is interpreted as both nominal value and maximum value (with added entry '​max.':​ lower tolerance = value) or minimum value (with added entry '​min.':​ upper tolerance = value). |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  |+^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Create ​nominal ​value and limit value as tolerances | Stipulates that the value entered is interpreted as both nominal value and maximum value (with added entry '​max.':​ lower tolerance = value) or minimum value (with added entry '​min.':​ upper tolerance = value). |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  |
 ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Create limit value only | Stipulates that an upper limit value (“max.”) is interpreted as upper tolerance and a lower limit value (“min.”) as lower tolerance. The nominal value and the remaining tolerance in each case are given a value of zero. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_1.png?​nolink&​0x50 |}}  | ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Create limit value only | Stipulates that an upper limit value (“max.”) is interpreted as upper tolerance and a lower limit value (“min.”) as lower tolerance. The nominal value and the remaining tolerance in each case are given a value of zero. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_1.png?​nolink&​0x50 |}}  |
 ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Ignore added entry “min./​max.” | Stipulates that the added entry “min.” or “max.” is ignored and the value entered is interpreted as generally toleranced nominal value. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  | ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Ignore added entry “min./​max.” | Stipulates that the added entry “min.” or “max.” is ignored and the value entered is interpreted as generally toleranced nominal value. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  |
 ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen.png?​nolink&​0x50 |}}  ^ Do not apply zero values in characteristic | Stipulates that the zero values mentioned above are not applied in the “nominal value”, “upper tolerance” or “lower tolerance” fields. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen_1.png?​nolink&​0x50 |}}  | ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen.png?​nolink&​0x50 |}}  ^ Do not apply zero values in characteristic | Stipulates that the zero values mentioned above are not applied in the “nominal value”, “upper tolerance” or “lower tolerance” fields. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen_1.png?​nolink&​0x50 |}}  |
 +
 +Possible settings based on an example, default setting highlighted in gray:
 +
 +{{ :​en:​infra-convert:​user:​settings:​einstellungen_grenzmasse_in_eine_richtung.png?​nolink&​600 |}}
  
 > Up to the program version mentioned above: > Up to the program version mentioned above:
Line 208: Line 229:
 ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Nominal dimension = width of the tolerance zone; upper tol. = width of the tolerance zone; lower tol. = 0 | Specifies that the width of the tolerance zone during stamping is interpreted as the nominal dimension and as the upper tolerance value. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  | ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Nominal dimension = width of the tolerance zone; upper tol. = width of the tolerance zone; lower tol. = 0 | Specifies that the width of the tolerance zone during stamping is interpreted as the nominal dimension and as the upper tolerance value. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  |
 ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen.png?​nolink&​0x50 |}}  ^ Zero values are not applied in the characteristic | Specifies that the zero values named above are not applied in the "​Nominal dimension",​ "Upper tolerance"​ / "Lower tolerance"​ fields. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen_0.png?​nolink&​0x50 |}}  | ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen.png?​nolink&​0x50 |}}  ^ Zero values are not applied in the characteristic | Specifies that the zero values named above are not applied in the "​Nominal dimension",​ "Upper tolerance"​ / "Lower tolerance"​ fields. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen_0.png?​nolink&​0x50 |}}  |
 +
 +Possible settings based on an example, default setting highlighted in gray:
 +
 +{{ :​en:​infra-convert:​user:​settings:​einstellungen_form_und_lage.png?​nolink&​600 |}}
  
 \\  \\ 
Line 250: Line 275:
 ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Nominal dimension = 0; upper tol. = limit value; lower tol. = 0 | Specifies that the limit value from the surface specification in the characteristic is set as the upper tolerance limit. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_1.png?​nolink&​0x50 |}}  | ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Nominal dimension = 0; upper tol. = limit value; lower tol. = 0 | Specifies that the limit value from the surface specification in the characteristic is set as the upper tolerance limit. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_1.png?​nolink&​0x50 |}}  |
 ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Nominal dimension = limit value; upper tol. = limit value; lower tol. = 0 | Specifies that the limit value from the surface specification in the characteristic is set as the nominal dimension and upper tolerance limit. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  | ^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld.png?​nolink&​0x50 |}}  ^ Nominal dimension = limit value; upper tol. = limit value; lower tol. = 0 | Specifies that the limit value from the surface specification in the characteristic is set as the nominal dimension and upper tolerance limit. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_optionsfeld_0.png?​nolink&​0x50 |}}  |
-^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen.png?​nolink&​0x50 |}}  ^ Zero values are not applied in the characteristic | Specifies that the zero values named above are not applied in the "​Nominal dimension",​ "Upper tolerance"​ and "Lower tolerance"​ fields. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen_0.png?​nolink&​0x50 |}}  |+^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen.png?​nolink&​0x50 |}}  ^ Zero values are not applied in the characteristic | Specifies that the zero values named above are not applied in the "​Nominal dimension",​ "Upper tolerance"​ and "Lower tolerance"​ fields. |  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_kontrollkaestchen_1.png?​nolink&​0x50 |}}  | 
 + 
 +Possible settings based on an example, default setting highlighted in gray: 
 + 
 +{{ :​en:​infra-convert:​user:​settings:​einstellungen_oberflaechen.png?​nolink&​600 |}}
  
 \\  \\ 
  
-==== “Simplified ​surface specifications” group ====+==== “Simplified ​indications” group ====
  
 |< 100% 8% 22% 55% 15%>​| ​ |< 100% 8% 22% 55% 15%>​| ​
 ^  Option ​ ^^  Function ​ ^  Default setting ​ ^ ^  Option ​ ^^  Function ​ ^  Default setting ​ ^
-^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_flexgrid.png?​nolink&​0x50 |}}  ^ Simplified ​surface specifications:​ assign parameters ​A simplified surface specification consists of a reference ​(graphic symbol with key, plotted on the corresponding component surfaces) ​and an assignment ​of the corresponding surface parameter ​to another position on the drawingFor automatic assignment during ​stamping, ​each key can be assigned ​parameter with value in this table. |  x = Rz 4\\ y = Rz 25\\ z = Rz 100   |+^  {{ :​en:​infra-convert:​user:​functions:​icon_steuerelement_flexgrid.png?​nolink&​0x50 |}}  ^ Simplified ​indications ​The identifier ​(alpha and/or numeric) ​of a →[[de:​infra-convert:​user:​terms#​simplified_indications|simplified indications]] can be linked ​to the detailed indication in text form at this pointWhen stamping, ​such character strings (" ​key") recognized in the drawing are replaced by detailed specification ("value") and evaluated accordingly. |  x = Rz  4\\ y = Rz  25\\ z = Rz  100 ​  | 
 +  
 +\\ 
  
 <WRAP noprint> <WRAP noprint>
en/infra-convert/user/config/features.txt · Last modified: 2024/02/27 08:24 by me