This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
en:infra-convert:user:terms [2020/09/28 11:08] me |
en:infra-convert:user:terms [2023/03/24 21:47] me |
||
---|---|---|---|
Line 6: | Line 6: | ||
</WRAP> | </WRAP> | ||
- | ====== Terms ====== | + | <WRAP group> |
+ | <WRAP column 3.5%> | ||
+ | {{:en:icon_terms.png?nolink&30}} | ||
+ | </WRAP> | ||
+ | <WRAP column 91.5%> | ||
+ | <html><b><font size="+2">Terms</font></b></html> | ||
+ | </WRAP> | ||
+ | </WRAP> | ||
---- | ---- | ||
Important terms are explained in the following. | Important terms are explained in the following. | ||
+ | |||
+ | \\ | ||
<WRAP noprint> | <WRAP noprint> | ||
Line 41: | Line 50: | ||
**S**\\ | **S**\\ | ||
• [[en:infra-convert:user:terms#Simplified indications]]\\ | • [[en:infra-convert:user:terms#Simplified indications]]\\ | ||
+ | • [[en:infra-convert:user:terms#Single/multiple characteristic]]\\ | ||
• [[en:infra-convert:user:terms#Specification operators and modifiers (ISO GPS)]]\\ | • [[en:infra-convert:user:terms#Specification operators and modifiers (ISO GPS)]]\\ | ||
• [[en:infra-convert:user:terms#Stamp/stamps]]\\ | • [[en:infra-convert:user:terms#Stamp/stamps]]\\ | ||
Line 66: | Line 76: | ||
<WRAP column 35%> | <WRAP column 35%> | ||
- | Click to zoom in: | + | (Click to zoom in) |
{{:en:infra-convert:user:terms:kantenglaettung_muster.png?direct&250| }} | {{:en:infra-convert:user:terms:kantenglaettung_muster.png?direct&250| }} | ||
Line 102: | Line 112: | ||
^ Standard characteristic | Characteristic that is not assigned to any of the following categories. | – | | ^ Standard characteristic | Characteristic that is not assigned to any of the following categories. | – | | ||
^ Special characteristic | A critical characteristic that deserves special attention. If the implementation of the characteristic does not correspond to the drawing specifications, a potential risk to functions (operational safety, interchangeability, service life, etc.) has to be expected to a great extent.\\ \\ Example of tagging:\\ {{ :en:infra-convert:user:terms:grafik_besondere_merkmale.png?nolink&420| }} | – | | ^ Special characteristic | A critical characteristic that deserves special attention. If the implementation of the characteristic does not correspond to the drawing specifications, a potential risk to functions (operational safety, interchangeability, service life, etc.) has to be expected to a great extent.\\ \\ Example of tagging:\\ {{ :en:infra-convert:user:terms:grafik_besondere_merkmale.png?nolink&420| }} | – | | ||
- | ^ Auxiliary measurement | Measurement that is not required for the geometric determination of a part and is not considered an integral part of the contract.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_hilfsmasse.png?nolink&420| }} | • DIN 406-10:1992-12 | | + | ^ Auxiliary measurement | Measurement that is not required for the geometric determination of a part and is not considered an integral part of the contract.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_hilfsmasse.png?nolink&420| }} | • DIN EN ISO 129-1 | |
- | ^ Rough measurement | Measurement that refers to the initial state of an object.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_rohmasse.png?nolink&420| }} | • DIN 406-10:1992-12 | | + | ^ Rough measurement | Measurement that refers to the initial state of an object.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_rohmasse.png?nolink&420| }} | • DIN 406-10 | |
- | ^ Theoretically accurate measurement | Measurement for indication of the geometrically ideal (theoretically precise) position or shape of the dimensioned shape element.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_theoretisch_genaue_masse.png?nolink&420| }} | • DIN 406-10:1992-12 | | + | ^ Theoretically accurate measurement | Measurement for indication of the geometrically ideal (theoretically precise) position or shape of the dimensioned shape element.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_theoretisch_genaue_masse.png?nolink&420| }} | • DIN EN ISO 129-1 | |
- | ^ Test measurement | Measurement that must be given special attention when determining the extent of the test / test accuracy.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_pruefmasse.png?nolink&420| }} | • DIN 406-10:1992-12 | | + | ^ Test measurement | Measurement that must be given special attention when determining the extent of the test / test accuracy.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_pruefmasse.png?nolink&420| }} | • DIN 406-10 | |
\\ | \\ | ||
Line 478: | Line 488: | ||
> In #@IC_HTML@#, character-coded texts or embedded fonts are a prerequisite for automatic feature recognition. | > In #@IC_HTML@#, character-coded texts or embedded fonts are a prerequisite for automatic feature recognition. | ||
+ | |||
+ | \\ | ||
+ | |||
+ | ==== Drawing data format: PDF ==== | ||
<WRAP group> | <WRAP group> | ||
Line 484: | Line 498: | ||
The PDF format (PDF = "Portable Document Format") supports raster-based and vector-based data storage. Coded text characters are stored in text fields, such as "⌀ 20" in the adjacent example. | The PDF format (PDF = "Portable Document Format") supports raster-based and vector-based data storage. Coded text characters are stored in text fields, such as "⌀ 20" in the adjacent example. | ||
- | > In #@IC_HTML@#, drawings in raster-based PDF format can be stamped manually using the quick input dialog. Drawings in vector-based PDF format can be stamped automatically* if the characters are coded.\\ \\ * A pro license is required.\\ \\ **See**\\ Functions > Characteristics > [[en:infra-convert:user:functions:ballooning_man|Manually stamp]]\\ Functions > Characteristics > [[en:infra-convert:user:functions:ballooning|Automatic stamping]] | + | > In #@IC_HTML@#, drawings in raster-based PDF format can be stamped manually using the quick input dialog. PDF drawing files can be stamped automatically*, if the characters are encoded.\\ \\ * A pro license is required.\\ \\ **See**\\ Functions > Characteristics > [[en:infra-convert:user:functions:ballooning_man|Manually stamp]]\\ Functions > Characteristics > [[en:infra-convert:user:functions:ballooning|Automatic stamping]] |
</WRAP> | </WRAP> | ||
Line 523: | Line 537: | ||
\\ | \\ | ||
+ | |||
+ | ==== Drawing data format: CAD exchange format ==== | ||
<WRAP group> | <WRAP group> | ||
Line 666: | Line 682: | ||
^ ::: ^ Pound-force-inch*² | lbf-i | – | PoundForceInch | | ^ ::: ^ Pound-force-inch*² | lbf-i | – | PoundForceInch | | ||
^ ::: ^ Pound-force-foot*² | lbf-ft | – | PoundForceFoot | | ^ ::: ^ Pound-force-foot*² | lbf-ft | – | PoundForceFoot | | ||
- | ^ Effort ^ Milliwatt*³ | mW | DIN 1301-1:2010-10 | MilliWatt | | + | ^ Effort ^ Milliwatt*³ | mW | DIN 1301-1:2010-10 | Milliwatt | |
^ ::: ^ Watt*³ | W | DIN 1301-1:2010-10 | Watt | | ^ ::: ^ Watt*³ | W | DIN 1301-1:2010-10 | Watt | | ||
- | ^ ::: ^ Kilowatt*³ | kW | DIN 1301-1:2010-10 | KiloWatt | | + | ^ ::: ^ Kilowatt*³ | kW | DIN 1301-1:2010-10 | Kilowatt | |
^ Temperature ^ Degrees Celsius | °C | DIN 1301-1:2010-10 | Celsius | | ^ Temperature ^ Degrees Celsius | °C | DIN 1301-1:2010-10 | Celsius | | ||
^ ::: ^ Degrees Fahrenheit | °F | [NIST-19] | Fahrenheit | | ^ ::: ^ Degrees Fahrenheit | °F | [NIST-19] | Fahrenheit | | ||
Line 675: | Line 691: | ||
^ ::: ^ Ampere*³ | A | DIN 1301-1:2010-10 | Ampere | | ^ ::: ^ Ampere*³ | A | DIN 1301-1:2010-10 | Ampere | | ||
^ ::: ^ Ohm*³ | Ω | DIN 1301-1:2010-10 | Ohm | | ^ ::: ^ Ohm*³ | Ω | DIN 1301-1:2010-10 | Ohm | | ||
- | ^ ::: ^ Ampere per centimeter*⁴ | A/cm | - | AmperePerCentimeter | | + | ^ ::: ^ Ampere per centimeter*⁴ | A/cm | – | AmperePerCentimeter | |
- | ^ ::: ^ Ampere per meter*⁴ | A/m | - | AmperePerMeter | | + | ^ ::: ^ Ampere per meter*⁴ | A/m | – | AmperePerMeter | |
- | ^ ::: ^ Millitesla*⁴ | mT | - | MilliTesla | | + | ^ ::: ^ Millitesla*⁴ | mT | – | MilliTesla | |
^ ::: ^ Tesla*⁴ | T | - | Tesla | | ^ ::: ^ Tesla*⁴ | T | - | Tesla | | ||
+ | ^ Sound ^ Phon*⁵ | phon | – | Phon | | ||
+ | ^ ::: ^ Sone*⁵ | sone | – | Sone | | ||
^ Level ^ Decibel*³ | dB | DIN 5493:2013-10 | Decibel | | ^ Level ^ Decibel*³ | dB | DIN 5493:2013-10 | Decibel | | ||
^ Auxiliary units ^ Number (of pieces)*³ | pcs = Stk. | – | Piece | | ^ Auxiliary units ^ Number (of pieces)*³ | pcs = Stk. | – | Piece | | ||
Line 684: | Line 702: | ||
^ ::: ^ Percent*¹ | % | DIN 5466:1983-02 | Percent | | ^ ::: ^ Percent*¹ | % | DIN 5466:1983-02 | Percent | | ||
^ ::: ^ Mol*³ | mol | DIN 1301-1:2010-10 | Mol | | ^ ::: ^ Mol*³ | mol | DIN 1301-1:2010-10 | Mol | | ||
- | | NIST-19: National Institute of Standards and Technology, Gaithersburg, Maryland, USA: NIST Handbook 44 : Specifications, Tolerances, and Other Technical Requirements for Weighing and Measuring Devices (Appendix C. General Tables of Units of Measurement) 2019.\\ *¹ Available from program version 1.2.0.23\\ *² Available from program version 1.3.9.5\\ *³ Available from program version 1.3.9.8\\ *⁴ Available from program version 2.1.1 ||||| | + | | NIST-19: National Institute of Standards and Technology, Gaithersburg, Maryland, USA: NIST Handbook 44 : Specifications, Tolerances, and Other Technical Requirements for Weighing and Measuring Devices (Appendix C. General Tables of Units of Measurement) 2019.\\ *¹ Available from program version 1.2.0.23\\ *² Available from program version 1.3.9.5\\ *³ Available from program version 1.3.9.8\\ *⁴ Available from program version 2.1.1\\ *⁵ Available from program version 2.10.0 ||||| |
\\ | \\ | ||
Line 759: | Line 777: | ||
\\ | \\ | ||
+ | |||
+ | ==== Single/multiple characteristic ==== | ||
+ | |||
+ | →[[en:infra-convert:user:terms#characteristic_test-_quality|Characteristics]] are derived from drawing entries. If a drawing entry collectively specifies several similar geometric elements of a component and each of these geometric elements is to be checked individually, further **individual characteristics** are derived from the original characteristic. In #@IC_HTML@# three possibilities are available for this. | ||
+ | |||
+ | <WRAP group> | ||
+ | <WRAP column half> | ||
+ | **Multiple characteristic** | ||
+ | |||
+ | A ** multiple characteristic** is linked to the drawing entry via a stamp containing the basic number ("1"). Depending on its property "number of repetitions", a corresponding number of individual characteristics are provided in the test plan ("1.1", "1.2", "1.3") and exported. However, the properties can only be edited comprehensively for the multiple characteristic. | ||
+ | |||
+ | > **See** User interface > Function windows > Characteristic properties> [[en:infra-convert:user:interface:feature#properties|Properties]] | ||
+ | > | ||
+ | > **See** Settings > Settings > Characteristics > [[en:infra-convert:user:config:features#dimensions_with_details_of_repetitions_group|“Dimensions with details of repetitions” group]] | ||
+ | |||
+ | </WRAP> | ||
+ | <WRAP column half> | ||
+ | {{ :en:infra-convert:user:terms:mehrfachmerkmale_wiederholungen.png?nolink&400 |}} | ||
+ | </WRAP> | ||
+ | </WRAP> | ||
+ | |||
+ | \\ | ||
+ | |||
+ | <WRAP group> | ||
+ | <WRAP column half> | ||
+ | **Duplicated Characteristic** | ||
+ | |||
+ | The **Duplicate** function creates a copy of a characteristic with its own stamp. The characteristic properties can be edited independently. However, the copies remain linked to each other by the stamp number. | ||
+ | |||
+ | > **See** Functions > Characteristics > [[en:infra-convert:user:functions:duplicate|Duplicate and re-stamp]] | ||
+ | </WRAP> | ||
+ | <WRAP column half> | ||
+ | {{ :en:infra-convert:user:terms:mehrfachmerkmale_dupliziert.png?nolink&800 |}} | ||
+ | </WRAP> | ||
+ | </WRAP> | ||
+ | |||
+ | \\ | ||
+ | |||
+ | <WRAP group> | ||
+ | <WRAP column half> | ||
+ | **Erneut gestempeltes Merkmal** | ||
+ | |||
+ | The **Re-stamp** function creates a copy of a characteristic with its own stamp. The copies are not linked together. The characteristic properties, including the stamp number, can be edited independently. | ||
+ | |||
+ | > **See** Functions > Characteristics > [[en:infra-convert:user:functions:duplicate|Duplicate and re-stamp]] | ||
+ | </WRAP> | ||
+ | <WRAP column half> | ||
+ | {{ :en:infra-convert:user:terms:mehrfachmerkmale_erneut_gestempelt.png?nolink&800 |}} | ||
+ | </WRAP> | ||
+ | </WRAP> | ||
+ | |||
+ | \\ | ||
+ | |||
+ | ---- | ||
+ | |||
+ | \\ | ||
+ | |||
==== Specification operators and modifiers (ISO GPS) ==== | ==== Specification operators and modifiers (ISO GPS) ==== | ||
Line 1006: | Line 1081: | ||
<WRAP rightalign> | <WRAP rightalign> | ||
**Go to previous page**\\ | **Go to previous page**\\ | ||
- | More > [[en:infra-convert:user:collectdrw|Create test plans from a collective drawing]] | + | More > [[en:infra-convert:user:ic_cec_cal|From the drawing to the measuring program in ZEISS CALYPSO]] |
</WRAP> | </WRAP> | ||
- | \\ | + | **Go to next page**\\ |
+ | More > [[en:infra-convert:faq|Frequently asked questions and answers]] | ||
\\ | \\ | ||