User Tools

Site Tools


en:infra-convert:dev:export:jsonv1

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
en:infra-convert:dev:export:jsonv1 [2020/02/03 12:45]
me [Characteristics]
en:infra-convert:dev:export:jsonv1 [2020/06/19 14:44]
me
Line 196: Line 196:
  
 The sequence of the characteristics corresponds to the list item in the test plan. The drawing-sheet-related inspection plan sections are hung together according to the sheet sequence. The sequence of the characteristics corresponds to the list item in the test plan. The drawing-sheet-related inspection plan sections are hung together according to the sheet sequence.
 +
 +At the end of this section you will find a diagram that illustrates how the IDs are assigned.
  
 > **See also** > **See also**
Line 273: Line 275:
 ^ Tolerance​Table | String | Name of the tolerance table\\ **null** No value assigned because parameter does not apply | ^ Tolerance​Table | String | Name of the tolerance table\\ **null** No value assigned because parameter does not apply |
 ^ Tolerance​Table​Column | String | Column in the tolerance table\\ **null** No value assigned because parameter does not apply | ^ Tolerance​Table​Column | String | Column in the tolerance table\\ **null** No value assigned because parameter does not apply |
-^ MinMax | String | **min** Type of limit: Minimum size (the lower limit is given, the upper limit is naturally)\\ **max** Type of limits: Maximum size (the upper limit is given, the lower limit is naturally)\\ **None** Both limit sizes are specified or a limit size specification is not applicable. |+^ MinMax | String | **min** Type of limit: Minimum size (the lower limit is given, the upper limit is naturally ​determined)\\ **max** Type of limits: Maximum size (the upper limit is given, the lower limit is naturally ​determined)\\ **None** Both limit sizes are specified or a limit size specification is not applicable. |
 ^ Fit | String | Tolerance class\\ **null** No value assigned because parameter does not apply | ^ Fit | String | Tolerance class\\ **null** No value assigned because parameter does not apply |
 ^ Conditions | String| Modifiers\\ **null** No value assigned because parameter does not apply | ^ Conditions | String| Modifiers\\ **null** No value assigned because parameter does not apply |
Line 297: Line 299:
  
 \\  \\ 
 +
 +> **Allocation of characteristic and stamp IDs**
 +> The following diagram illustrates the assignment of the Ids (Guids) across the inspection plan versions. In case 1, a characteristic is transferred from test plan version A to B and from B to C in the drawing comparison. For example, "Guid C1" is found in version B as a CompareSourceId and as a DirectCompareSourceId,​ in C consequently only as CompareSourceId. In case 2, inspection plan version B is omitted.
 +
 +> {{ :​de:​infra-convert:​user:​terms:​id-zuweisung_beim_zeichnungsvergleich.png?​nolink&​850 |}}
 +
 +\\
  
 ====== Classes ====== ====== Classes ======
en/infra-convert/dev/export/jsonv1.txt · Last modified: 2023/02/10 11:29 by me