This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
en:infra-convert:dev:export:jsonv1 [2020/06/18 14:36] me |
en:infra-convert:dev:export:jsonv1 [2020/06/19 14:44] me |
||
---|---|---|---|
Line 275: | Line 275: | ||
^ ToleranceTable | String | Name of the tolerance table\\ **null** No value assigned because parameter does not apply | | ^ ToleranceTable | String | Name of the tolerance table\\ **null** No value assigned because parameter does not apply | | ||
^ ToleranceTableColumn | String | Column in the tolerance table\\ **null** No value assigned because parameter does not apply | | ^ ToleranceTableColumn | String | Column in the tolerance table\\ **null** No value assigned because parameter does not apply | | ||
- | ^ MinMax | String | **min** Type of limit: Minimum size (the lower limit is given, the upper limit is naturally)\\ **max** Type of limits: Maximum size (the upper limit is given, the lower limit is naturally)\\ **None** Both limit sizes are specified or a limit size specification is not applicable. | | + | ^ MinMax | String | **min** Type of limit: Minimum size (the lower limit is given, the upper limit is naturally determined)\\ **max** Type of limits: Maximum size (the upper limit is given, the lower limit is naturally determined)\\ **None** Both limit sizes are specified or a limit size specification is not applicable. | |
^ Fit | String | Tolerance class\\ **null** No value assigned because parameter does not apply | | ^ Fit | String | Tolerance class\\ **null** No value assigned because parameter does not apply | | ||
^ Conditions | String| Modifiers\\ **null** No value assigned because parameter does not apply | | ^ Conditions | String| Modifiers\\ **null** No value assigned because parameter does not apply | | ||
Line 301: | Line 301: | ||
> **Allocation of characteristic and stamp IDs** | > **Allocation of characteristic and stamp IDs** | ||
- | > The following diagram illustrates the assignment of the Ids (guides) across the inspection plan versions. In case 1, a characteristic is transferred from inspection plan version A to B and from B to C in the drawing comparison. For example, "Guid C1" is found in version B as a CompareSourceId and as a DirectCompareSourceId, in C consequently only as CompareSourceId. In case 2, inspection plan version B is omitted. | + | > The following diagram illustrates the assignment of the Ids (Guids) across the inspection plan versions. In case 1, a characteristic is transferred from test plan version A to B and from B to C in the drawing comparison. For example, "Guid C1" is found in version B as a CompareSourceId and as a DirectCompareSourceId, in C consequently only as CompareSourceId. In case 2, inspection plan version B is omitted. |
> | > | ||
> {{ :de:infra-convert:user:terms:id-zuweisung_beim_zeichnungsvergleich.png?nolink&850 |}} | > {{ :de:infra-convert:user:terms:id-zuweisung_beim_zeichnungsvergleich.png?nolink&850 |}} |