en:infra-convert:dev:parameter [2020/01/28 15:27]
me [Export quality test plans and stamped drawings]
en:infra-convert:dev:parameter [2020/07/29 16:40]
me [Settings]
Line 317: Line 317:
 ^  Parameter ​ ^  Type  ^  Value/​Content ​ ^ ^  Parameter ​ ^  Type  ^  Value/​Content ​ ^
 ^ ImportBehavior | String | Behaviour when importing DXF and DWG files:\\ **Ask** Allways ask before import\\ **ImportModel** Always import model space only\\ **ImportPaperSpaces** Always import all sheets from paper space\\ **ImportAllLayouts** Allways import all sheets\\ \\ **Note** The parameter is optional. If it is not specified, the sheet is imported from model space. Available from program version 1.4.1.17 | ^ ImportBehavior | String | Behaviour when importing DXF and DWG files:\\ **Ask** Allways ask before import\\ **ImportModel** Always import model space only\\ **ImportPaperSpaces** Always import all sheets from paper space\\ **ImportAllLayouts** Allways import all sheets\\ \\ **Note** The parameter is optional. If it is not specified, the sheet is imported from model space. Available from program version 1.4.1.17 |
 +
 +This applies to the import of ICP project files:
 +
 +|< 100% 33% 12% 54% >|
 +^  Parameter ​ ^  Type  ^  Value/​Content ​ ^
 +^ ImportBehavior | String | Behavior when importing ICP files:\\ **Ask** When reloading PDF, DXF and DWG drawing files, ask the user to select the page or sheet in the file\\ **ImportModel** When reloading DXF and DWG files, always import the model space only\\ \\ **Note** The parameter is optional. If it is not specified, the first page is automatically selected from a PDF file or the model space is selected in a DXF and DWG file. Available from program version 1.5.1.1 |
  
 </​WRAP>​ </​WRAP>​
Line 593: Line 599:
  
 The path to the parameter file //​Settings.json//​ is specified in the **Settings** field. #@IC_HTML@# obtains the global settings from this file. The path to the parameter file //​Settings.json//​ is specified in the **Settings** field. #@IC_HTML@# obtains the global settings from this file.
- 
-> **Please note** Changes made by the user in the user interface are not written to the "​settings.json"​ loaded here, but to the "​settings.json"​ in the CommonAppData directory whose path is defined in the "​settings.json"​ with the parameter "​CommonAppDataPath"​. 
  
 > **See also** > **See also**
Line 615: Line 619:
 ^  Parameter ​ ^  Type  ^  Value/​Content ​ ^ ^  Parameter ​ ^  Type  ^  Value/​Content ​ ^
 ^ Path | String | Path to the location and file name; the directory names must be separated by slash characters ("/"​) or double backslash characters ("​\\"​). | ^ Path | String | Path to the location and file name; the directory names must be separated by slash characters ("/"​) or double backslash characters ("​\\"​). |
 +^ Force | String | Reading order of the parameters passed by start parameter and a user-defined "​settings.json":​\\ **true** Force the "​settings.json"​ passed by start parameter to be read from AppData after the "​settings.json",​ thus overwriting user-defined settings\\ **false** Default behaviour (also applies if parameter "​Force"​ is not specified)\\ \\ **Note** Available from program version 2.0.0.0 |
  