User Tools

Site Tools


en:infra-convert:user:cadexp:nx_10

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Last revision Both sides next revision
en:infra-convert:user:cadexp:nx_10 [2017/07/06 12:06]
me
en:infra-convert:user:cadexp:nx_10 [2023/03/19 14:08]
me
Line 1: Line 1:
 ~~NOTOC~~ ~~NOTOC~~
- 
-{{ :​en:​icon_uebersetzung_in_arbeit.png?​nolink&​150 |}} 
  
 <WRAP noprint> <WRAP noprint>
  
-Benutzerhandbuch ​#@IC_HTML@# > CAD-Zeichnungsexport ​> Siemens PLM+User manual ​#@IC_HTML@# > Export drawing from the CAD system ​> Siemens PLM
  
 </​WRAP>​ </​WRAP>​
  
-====== ​Solid Edge ST2 ======+====== ​NX (from version 10) ======
  
 ---- ----
  
-Diese Anleitung beschreibt den Export von Zeichnungsdateien im DWG-, DXF- und IGES-Format (→[[en:​infra-convert:​user:​terms#​Zeichnungsdatenformat|Zeichnungsdatenformat]]) aus dem CAD-System ​"Solid Edge ST2" ​herausMit den empfohlenen Einstellungen stellen Sie sicher, dass die Zeichnungsdatei von #​@IC_HTML@# ​bestmöglich gelesen werden kann.+Described are export settings for the CAD system ​"Siemens NX" ​from version 10With the recommended settings you ensure that the drawing file can be read by #​@IC_HTML@# ​in the best possible way.
  
 +Basically, it should be noted that fonts must be installed on the respective PC when processing drawing files in an exchange format, such as DXF, DWG or PDF.\\  **See** [[en:​infra-convert:​user:​fonts|Dealing with missing fonts]]
 +
 +If an export result is not satisfactory despite the configuration recommendations,​ we will be happy to support you directly.
 +
 +\\ 
  
 <WRAP noprint> <WRAP noprint>
 <WRAP group> <WRAP group>
 <WRAP column 20%> <WRAP column 20%>
-//**__Inhalt__**//+//**__Content__**//
  
- • [[en:​infra-convert:​user:​cadexp:​solid_edge_st2#DWG-Export]]\\  + • [[en:​infra-convert:​user:​cadexp:​nx_10#DXF/DWG export]]\\  
- • [[en:​infra-convert:​user:​cadexp:​solid_edge_st2#DXF-Export]]\\  + • [[en:​infra-convert:​user:​cadexp:​nx_10#IGES export]]\\  
- • [[en:​infra-convert:​user:​cadexp:​solid_edge_st2#IGES-Export]]+ • [[en:​infra-convert:​user:​cadexp:​nx_10#PDF export]]
  
 \\  \\ 
Line 31: Line 34:
 </​WRAP>​ </​WRAP>​
  
-==== DWG-Export ​====+==== DXF/DWG export ​====
  
-|< 100% 5% 20% 75%>| +Manufacturer'​s documentation for DXF/DWG export ​(from version 12): [[https://​docs.plm.automation.siemens.com/​tdoc/​nx/​12/​nx_help#​uid:​xid1128422:​index_xid458383:​xid458366|Siemens documentation:​ DXF/DWG export]].
-^  Schritt ​ ^^  Aktion/Ergebnis ​ ^ +
-^  1  ^ Menü "​Speichern unter" öffnen | Öffnen Sie das Applikationsmenü ​(Solid Edge-Logo oben links im Fensterund klicken Sie auf **Speichern unter** > **Als übersetzt speichern**.\\ Es öffnet sich der Dateimanager+
-^  2  ^ Zeichnung speichern | Wählen Sie als Dateityp **AutoCAD-Dokumente (*.dwg)** aus und führen Sie den Speichervorgang wie gewohnt zu Ende. |+
  
-==== DXF-Export ====+Recommended configurations:​
  
-|< 100% 5% 20% 75%>+{{page>en:infra-convert:​user:​cadexp:​dxf_dwg_version_note}}
-^  Schritt ​ ^^  Aktion/​Ergebnis ​ ^ +
-^  1  ^ Menü "​Speichern unter" öffnen | Öffnen Sie das Applikationsmenü (Solid Edge-Logo oben links im Fenster) und klicken Sie auf **Speichern unter** > **Als übersetzt speichern**.\\ Es öffnet sich der Dateimanager. | +
-^  2  ^ Zeichnung speichern | Wählen Sie als Dateityp **AutoCAD-Dokumente (*.dxf)** aus und führen Sie den Speichervorgang wie gewohnt zu Ende. |+
  
-==== IGES-Export ====+|< 100% 7.5% 22.5% 70%>| 
 +^ {{ en:infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_101.png?​nolink&​50 |}} ^ Drafting preferences | **File** > **Drafting preferences** > **View** > **Workflow** > **Border** [[https://​docs.plm.automation.siemens.com/​tdoc/​nx/​12/​nx_help/#​uid:​xid629526|{{:​en:​icon_link.png|}}]]\\ └  Display:​ **Off**\\ \\ Version 10:​    Version 12:\\ {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_10_001.png?​direct&​0x100|}}  {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_001.png?​direct&​0x100|}} | 
 +^ {{ en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_108.png?​nolink&​50 |}} ^ Load Settings | **File** > **Export** > **AutoCAD DXF/​DWG…** > **Load Settings** [[https://​docs.plm.automation.siemens.com/​tdoc/​nx/​12/​nx_help#​uid:​xid1128422:​index_xid458383:​xid458366:​xid454319|{{:​en:​icon_link.png|}}]]\\ └  Load From:​ Settings file (*.def)*\\ \\ * The configuration file should contain the following value assignment:​ [[https://​docs.plm.automation.siemens.com/​tdoc/​nx/​12/​nx_help/#​uid:​xid1396811|{{:​en:​icon_link.png|}}]]\\ └  UGI_GDT_EXPORT_AS_BLOCK ​NO\\ \\ The path to the configuration file for the DXF/DWG translator can also be set once by environment variable NX_DXFDWG_DEF. [[https://​docs.plm.automation.siemens.com/​tdoc/​nx/​1899/​nx_help#​uid:​xid1128422:​index_dataexchange:​xid1579771|{{:​de:​icon_link.png|}}]] | 
 +^ {{ en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_102.png?​nolink&​50 |}} ^ Input and Output | **File** > **Export** > **AutoCAD DXF/​DWG…** > **Input and Output** [[https://​docs.plm.automation.siemens.com/​tdoc/​nx/​12/​nx_help#​uid:​xid1128422:​index_xid458383:​xid458366:​xid454319|{{:​en:​icon_link.png|}}]]\\ └  Export To:​ **DXF** or **DWG**\\ └  Export As:​ **2D**\\ └  Output to:​ **Modeling**\\ └  Output to:​ **Layout**​*\\ \\  * #@IC_HTML@# Per required\\ \\ Version 10:​       Version 12:​       Version 1899:\\ {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_10_002.png?​direct&​0x100|}}  {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_002.png?​direct&​0x100|}}  {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_1899_001.png?​direct&​0x100|}} | 
 +^ {{ en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_103.png?​nolink&​50 |}} ^ Data to Export | **File** > **Export** > **AutoCAD DXF/​DWG…** > **Data to Export** [[https://​docs.plm.automation.siemens.com/​tdoc/​nx/​12/​nx_help#​uid:​xid1128422:​index_xid458383:​xid458366:​xid454319|{{:​en:​icon_link.png|}}]]\\ └  Model Data/​Drawing:​ **Drawing**\\ \\ Version 10:​       Version 12:​       Version 1899:\\ {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_10_003.png?​direct&​0x100|}}  {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_003.png?​direct&​0x100|}}  {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_1899_002.png?​direct&​0x100|}} | 
 +^ {{ en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_104.png?​nolink&​50 |}} ^ Options | **File** > **Export** > **AutoCAD DXF/​DWG…** > **Options** [[https://​docs.plm.automation.siemens.com/​tdoc/​nx/​12/​nx_help#​uid:​xid1128422:​index_xid458383:​xid458366:​xid454319|{{:​en:​icon_link.png|}}]]\\ └  DXF/DWG Revision:​ see "​General - DXF/DWG version"​ above\\ └  Export Spline As:​ **Spline**\\ └  Remove Overlapping Entities:​ **No**\\ └  Scale Option:​ **No Scale**\\ └  Scale Value:​ **1.0000**\\ \\ Version 10:​       Version 12:​       Version 1899:\\ {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_10_004.png?​direct&​0x100|}}  {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_004.png?​direct&​0x100|}}  {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_1899_003.png?​direct&​0x100|}} | 
 +^ {{ en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_105.png?​nolink&​50 |}} ^ Fonts | **File** > **Export** > **AutoCAD DXF/​DWG…** > **Fonts** [[https://​docs.plm.automation.siemens.com/​tdoc/​nx/​12/​nx_help#​uid:​xid1128422:​index_xid458383:​xid458366:​xid454319|{{:​en:​icon_link.png|}}]]\\ └  Text Width:​ **Use NX Aspect Ratio**\\ └  latin_extended:​ **isocp.shx**\\ \\ Version 10:​       Version 12:​       Version 1899:\\ {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_10_005.png?​direct&​0x100|}}  {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_005.png?​direct&​0x100|}}  {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_1899_004.png?​direct&​0x100|}} |
  
-|< 100% 5% 2075%>| +\\  
- ​Schritt ​ ^ ​Aktion/Ergebnis ​ ^ + 
-^  ​ ^ Menü "​Speichern unter" öffnen ​Öffnen Sie das Applikationsmenü (Solid Edge-Logo oben links im Fenster) und klicken Sie auf **Speichern unter** > **Als übersetzt speichern**.\\ Es öffnet sich der Dateimanager. | +==== IGES export ==== 
- ​2  ​Zeichnung speichern ​Wählen Sie als Dateityp ​**IGES-Dokumente ​(*.iges,*.igs)** aus und führen Sie den Speichervorgang wie gewohnt zu Ende. |+ 
 +Manufacturer'​s documentation for IGES export (from version 12): [[https://​docs.plm.automation.siemens.com/​tdoc/​nx/​12/​nx_help#​uid:​xid1128422:​index_xid458385|Siemens documentation:​ IGES translator]]. 
 + 
 +Recommended configurations:​ 
 + 
 +|< 100% 7.5% 22.570%>| 
 +{{ en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_101.png?​nolink&​50 |}} Drafting Preferences | **File** > **Drafting Preferences** > **View** > **Workflow** > **Border** [[https:​//​docs.plm.automation.siemens.com/​tdoc/​nx/​12/​nx_help/#​uid:​xid629526|{{:​en:​icon_link.png|}}]]\\ └  Display:​ **Off**\\ \\ Version 10:​    Version 12:\\ {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_10_001.png?​direct&​0x100|}}  {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_001.png?​direct&​0x100|}} | 
 +{{ en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_101.png?​nolink&​50 |}} ^ Files | **File** > **Export** > **Export to IGES Options** > **Files** [[https://​docs.plm.automation.siemens.com/​tdoc/​nx/​12/​nx_help/#​uid:​xid434343|{{:​en:​icon_link.png|}}]]\\ └  Export from:​ **Drawings**\\ └  Export to:​ **IGES file**\\ \\ Version 10:\\ {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_10_011.png?​direct&​0x100|}} | 
 +^ {{ en:infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_101.png?​nolink&​50 |}} ^ Data for Export | **File** > **Export** > **Export to IGES Options** > **Data for Export** [[https://​docs.plm.automation.siemens.com/​tdoc/​nx/​12/​nx_help/#​uid:​xid434343|{{:​en:​icon_link.png|}}]]\\ └  Export:​ **Selected Drawings**\\ \\ Version 10:\\ {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_10_012.png?​direct&​0x100|}} ​
 +{{ en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_101.png?​nolink&​50 |}} Advanced ​| **File** > **Export** > **Export to IGES Options** > **Advanced** [[https://​docs.plm.automation.siemens.com/​tdoc/​nx/​12/​nx_help/#​uid:​xid434343|{{:​en:​icon_link.png|}}]]\\ └  NX 3D to 2D options > Enclose facet body:​ **Yes**\\ └  NX 3D to 2D options > Convert GDT as a group:​ **No**\\ \\ Version 10:\\ {{en:infra-convert:​user:​cadexp:​cadexp_siemens_nx_10_013.png?​direct&​0x100|}} | 
 + 
 +\\  
 + 
 +==== PDF export ==== 
 + 
 +Manufacturer'​s documentation for PDF export ​(from Version 12): [[https://​docs.plm.automation.siemens.com/​tdoc/​nx/​12/​nx_help#​uid:​file_fil_exp_pdf_op|Dialog window "​Export PDF"​]]. 
 + 
 +Recommended configurations:​ 
 + 
 +|< 100% 7.5% 22.5% 70%>| 
 +^ {{ en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_12_101.png?​nolink&​50 |}} ^ Export PDF | **File** > **Export** > **PDF...** [[https://​docs.plm.automation.siemens.com/​tdoc/​nx/​12/​nx_help#​uid:​xid1128416:​index_working_with_files:​id1354112:​file_fil_exp_pdf_op|{{:​en:​icon_link.png|}}]]\\ └  Source:​ Select sheets\\ └  Colors: **Black on white**\\ └  Size:​ **Original size**\\ └  Output text:​ **Text**\\ └  Export grid images to drawing:​ **Yes**\\ └  Image resolution:​ **Medium** to **Hight**\\ \\ Version 10:\\ {{en:​infra-convert:​user:​cadexp:​cadexp_siemens_nx_10_021.png?​direct&​0x100|}}  ​|
  
 <WRAP noprint> <WRAP noprint>
Line 60: Line 83:
  
 <WRAP rightalign>​ <WRAP rightalign>​
-**Zurück zu**\\  +**Go to previous page**\\  
-CAD-Zeichnungsexport ​> Siemens PLM > [[en:​infra-convert:​user:​cadexp:​nx_10|NX 10]] +Export drawing from the CAD system ​> Siemens PLM > [[en:​infra-convert:​user:​cadexp:​nx_6|NX 6]]
 </​WRAP>​ </​WRAP>​
  
-**Weiter mit**\\  +**Go to next page**\\  
-Excel Report Add-In ​> [[en:​infra-convert:​add-in|Übersicht]]+Export drawing from the CAD system > Siemens PLM > [[en:​infra-convert:​user:​cadexp:​solid_edge_st2|Solid Edge ST2]]
  
 </​WRAP>​ </​WRAP>​
en/infra-convert/user/cadexp/nx_10.txt · Last modified: 2023/11/17 19:23 by me