User Tools

Site Tools


en:mdm:inputdevices:mahr-i-stick

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
en:mdm:inputdevices:mahr-i-stick [2016/01/27 13:48]
sh
en:mdm:inputdevices:mahr-i-stick [2018/03/02 13:12] (current)
me
Line 1: Line 1:
-===== Mahr i-Stick =====+~~NOTOC~~
  
-The additional module for **Mahr Integrated Wireless** measurement device is not included in the basic version of MDM-Tool.+<WRAP noprint>
  
-==== Connecting a Mahr Integrated Wireless measurement device ====+> Manual #​@MDM_HTML@#​ > Input Devices 
 + 
 +</​WRAP>​ 
 + 
 +====== Mahr i-Stick ====== 
 + 
 +---- 
 + 
 +<WRAP noprint>​ 
 +<WRAP group> 
 +<WRAP column 50%> 
 +//​**__Content__**//​ 
 + 
 + • [[en:​mdm:​inputdevices:​mahr-i-stick#​Connecting a Mahr Integrated Wireless measurement device]]\\  
 + • [[en:​mdm:​inputdevices:​mahr-i-stick#​Configuring a Mahr Integrated Wireless measurement device]]\\  
 + • [[en:​mdm:​inputdevices:​mahr-i-stick#​Configuring a Mahr i-Stick USB dongle]] 
 + 
 +\\  
 + 
 +</​WRAP>​ 
 +</​WRAP>​ 
 +</​WRAP>​ 
 + 
 +The additional module for **Mahr Integrated Wireless** measurement devices is not included in the basic version of MDM-Tool. 
 + 
 +===== Connecting a Mahr Integrated Wireless measurement device =====
  
 The following describes how to connect a Mahr Integrated Wireless measurement device to your PC. The following describes how to connect a Mahr Integrated Wireless measurement device to your PC.
Line 9: Line 34:
 {{:​en:​mdm:​inputdevices:​istick_a1_eng.png?​500|}} {{:​en:​mdm:​inputdevices:​istick_a1_eng.png?​500|}}
  
-Double click the **+ Add new device** entry field in the **blue-DAT** list to open the devices list. All measurement devices that are recognized are listed here.+Double click the **+ Add new device** entry field in the **Mahr i-Stick** list to open the devices list. All measurement devices that are recognized are listed here.
  
 {{:​en:​mdm:​inputdevices:​istick_a2_eng.png?​500|}} {{:​en:​mdm:​inputdevices:​istick_a2_eng.png?​500|}}
  
-Öffnen Sie nun das Menü des Messmittels ​(am Messmittel selbstnicht im MDM-Tool). Wechseln zur Einstellung der ID und setzen Sie diese zurückIm Display des Messmittels erscheint „——“Danach drücken Sie auf die Taste zum Übermitteln eines MesswertsDas Messmittel wird nun in der Liste angezeigt.+Now open the measurement device'​s configuration menu (the device'​s menunot the MDM'sand switch to ID configurationReset the device'​s ​ID. If the ID is properly reseted, the device'​s display shows "- - - - -"Now push the button for transmitting a measurement valueAfter a few seconds the measurement device should appear ​in the MDM-Tool'​s device list.
  
-Now open the measurement device'​s configuration menu (the device'​s menu, not the MDM's) and switch to the ID configuration. Reset the device'​s ID. If the ID is properly reseted, the device'​s display shows "​-----"​. Now push the button for transmitting a measurement value. After a few seconds the measurement device should appear in the MDM device list. +Select ​the measurement device you want to connect and click the **Add** ​button. The measurement device ​is now listed ​in the **Input devices** ​list and is automatically connected to the standard output device, the **Virtual Keyboard**. ​
- +
-Mouse click on the measurement device you want to connect and then click on **Add**. The measurement device now appears ​in the **Input devices** ​lists and is automatically connected to the standard output device, the **Virtual Keyboard**. ​+
  
 {{:​en:​mdm:​inputdevices:​istick_a3_eng.png?​500|}} {{:​en:​mdm:​inputdevices:​istick_a3_eng.png?​500|}}
  
 Pressing the button on the measurement device transmits measurement data from the device to keyboard interface. Transmitted measurement values are then displayed in the lower part of the window. As a check, compare these values with those displayed on your handheld measuring device. Pressing the button on the measurement device transmits measurement data from the device to keyboard interface. Transmitted measurement values are then displayed in the lower part of the window. As a check, compare these values with those displayed on your handheld measuring device.
-\\ + 
-\\ +The green icon next to the device shows you that the device is turned on. If the device is turned off, the icon turns yellow. 
-The green icon next to the device shows you that the device is turned on. If the device is turned off, the icon turns yellow. ​As additional information is displayed the battery level of the transmitter. +
-\\  +
-\\+
 <WRAP pagebreak></​WRAP>​ <WRAP pagebreak></​WRAP>​
-==== Configuring a Mahr Integrated ​Wirless ​measurement device ====+ 
 +===== Configuring a Mahr Integrated ​Wireless ​measurement device ​=====
  
 This section describes how to configure a Mahr Integrated Wirless measurement device. This section describes how to configure a Mahr Integrated Wirless measurement device.
 +
 +{{:​en:​mdm:​inputdevices:​istick_b1_eng.png?​500|}}
  
 Mouse click to select the device you want to configure from the list. Mouse click to select the device you want to configure from the list.
  
-{{:​en:​mdm:​inputdevices:​istick_b1_eng.png?500|}}+{{:​en:​mdm:​inputdevices:​istick_b2_eng.png?500|}}
  
 Click the **Configure** button below the list. You can also right-click to open the context menu and select **Configure** from the menu list. Click the **Configure** button below the list. You can also right-click to open the context menu and select **Configure** from the menu list.
  
-{{:​en:​mdm:​inputdevices:​istick_b2_eng.png?​500|}} 
 {{:​en:​mdm:​inputdevices:​istick_b3_eng.png?​500|}} {{:​en:​mdm:​inputdevices:​istick_b3_eng.png?​500|}}
  
Line 46: Line 69:
  
 The serial number and type of the measurement device are also displayed. These settings cannot be changed. ​ The serial number and type of the measurement device are also displayed. These settings cannot be changed. ​
- 
-{{:​en:​mdm:​inputdevices:​istick_b4_eng.png?​500|}} 
- 
-In the **Feedback** menu select the output device from which you expect acknowledgement of receipt for measurement data. If you select the **green LED** from the list, this LED on the transmitter will light up when measurement value has been processed. Selecting **Virtual COM Port** or **Virtual Keyboard** from the list results in this device taking on the acknowledgement of receipt and the corresponding LEDs light up.  
  
 Click **Delete** to remove the measurement device from the list. Click **Delete** to remove the measurement device from the list.
Line 56: Line 75:
  
 <WRAP pagebreak></​WRAP>​ <WRAP pagebreak></​WRAP>​
-==== Configuring a Mahr i-Stick USB dongle ====+ 
 +===== Configuring a Mahr i-Stick USB dongle ​=====
  
 This section describes how to configure a Mahr i-Stick USB dongle. ​ This section describes how to configure a Mahr i-Stick USB dongle. ​
Line 74: Line 94:
 The name of the COM port connected to the USB dongle is also displayed. This setting cannot be changed. ​ The name of the COM port connected to the USB dongle is also displayed. This setting cannot be changed. ​
  
-Click the **Close** or **Configure** buttons to close the window.+Click the **Close** buttons to close the window.
  
 <WRAP pagebreak></​WRAP>​ <WRAP pagebreak></​WRAP>​
 +
 +<WRAP noprint>
 +
 +----
 +
 +<WRAP group>
 +<WRAP col2>
 +
 +<WRAP rightalign>​
 +**Back to**\\ ​
 +Input Devices > [[en:​mdm:​inputdevices:​infra-dat|infra DAT]]
 +</​WRAP>​
 +
 +**Continue with**\\ ​
 +Input Devices > [[en:​mdm:​inputdevices:​mux|MUX-Protokoll]]
 +
 +</​WRAP>​
 +</​WRAP>​
 +
 +</​WRAP>​
en/mdm/inputdevices/mahr-i-stick.1453898912.txt.gz · Last modified: 2016/01/27 13:48 by sh