This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
en:infra-convert:user:terms [2021/02/22 14:23] me [Drawing data format: PDF] |
en:infra-convert:user:terms [2023/10/20 16:02] (current) me [Antialiasing] |
||
---|---|---|---|
Line 6: | Line 6: | ||
</WRAP> | </WRAP> | ||
- | ====== Terms ====== | + | <WRAP group> |
+ | <WRAP column 3.5%> | ||
+ | {{:en:icon_terms.png?nolink&30}} | ||
+ | </WRAP> | ||
+ | <WRAP column 91.5%> | ||
+ | <html><b><font size="+2">Terms</font></b></html> | ||
+ | </WRAP> | ||
+ | </WRAP> | ||
---- | ---- | ||
Important terms are explained in the following. | Important terms are explained in the following. | ||
+ | |||
+ | \\ | ||
<WRAP noprint> | <WRAP noprint> | ||
Line 62: | Line 71: | ||
<WRAP column 60%> | <WRAP column 60%> | ||
- | The right graph shows graphic exports from #@IC_HTML@# using the possible supersampling methods and with different quality levels (size of the original: 100 mm; exported as PNG with 300 dpi) Runtime and memory usage increase with the quality level and complexity of the algorithm from "average" to "Lanczos 3". | + | The right graph shows graphic exports from #@IC_HTML@# using the possible supersampling methods (software rendering) and with different quality levels (size of the original: 100 mm; exported as PNG with 300 dpi) Runtime and memory usage increase with the quality level and complexity of the algorithm from "average" to "Lanczos 3". |
</WRAP> | </WRAP> | ||
Line 103: | Line 112: | ||
^ Standard characteristic | Characteristic that is not assigned to any of the following categories. | – | | ^ Standard characteristic | Characteristic that is not assigned to any of the following categories. | – | | ||
^ Special characteristic | A critical characteristic that deserves special attention. If the implementation of the characteristic does not correspond to the drawing specifications, a potential risk to functions (operational safety, interchangeability, service life, etc.) has to be expected to a great extent.\\ \\ Example of tagging:\\ {{ :en:infra-convert:user:terms:grafik_besondere_merkmale.png?nolink&420| }} | – | | ^ Special characteristic | A critical characteristic that deserves special attention. If the implementation of the characteristic does not correspond to the drawing specifications, a potential risk to functions (operational safety, interchangeability, service life, etc.) has to be expected to a great extent.\\ \\ Example of tagging:\\ {{ :en:infra-convert:user:terms:grafik_besondere_merkmale.png?nolink&420| }} | – | | ||
- | ^ Auxiliary measurement | Measurement that is not required for the geometric determination of a part and is not considered an integral part of the contract.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_hilfsmasse.png?nolink&420| }} | • DIN 406-10:1992-12 | | + | ^ Auxiliary measurement | Measurement that is not required for the geometric determination of a part and is not considered an integral part of the contract.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_hilfsmasse.png?nolink&420| }} | • DIN EN ISO 129-1 | |
- | ^ Rough measurement | Measurement that refers to the initial state of an object.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_rohmasse.png?nolink&420| }} | • DIN 406-10:1992-12 | | + | ^ Rough measurement | Measurement that refers to the initial state of an object.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_rohmasse.png?nolink&420| }} | • DIN 406-10 | |
- | ^ Theoretically accurate measurement | Measurement for indication of the geometrically ideal (theoretically precise) position or shape of the dimensioned shape element.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_theoretisch_genaue_masse.png?nolink&420| }} | • DIN 406-10:1992-12 | | + | ^ Theoretically accurate measurement | Measurement for indication of the geometrically ideal (theoretically precise) position or shape of the dimensioned shape element.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_theoretisch_genaue_masse.png?nolink&420| }} | • DIN EN ISO 129-1 | |
- | ^ Test measurement | Measurement that must be given special attention when determining the extent of the test / test accuracy.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_pruefmasse.png?nolink&420| }} | • DIN 406-10:1992-12 | | + | ^ Test measurement | Measurement that must be given special attention when determining the extent of the test / test accuracy.\\ \\ Example for the tagging:\\ {{ :en:infra-convert:user:terms:grafik_pruefmasse.png?nolink&420| }} | • DIN 406-10 | |
\\ | \\ | ||
Line 673: | Line 682: | ||
^ ::: ^ Pound-force-inch*² | lbf-i | – | PoundForceInch | | ^ ::: ^ Pound-force-inch*² | lbf-i | – | PoundForceInch | | ||
^ ::: ^ Pound-force-foot*² | lbf-ft | – | PoundForceFoot | | ^ ::: ^ Pound-force-foot*² | lbf-ft | – | PoundForceFoot | | ||
- | ^ Effort ^ Milliwatt*³ | mW | DIN 1301-1:2010-10 | MilliWatt | | + | ^ Effort ^ Milliwatt*³ | mW | DIN 1301-1:2010-10 | Milliwatt | |
^ ::: ^ Watt*³ | W | DIN 1301-1:2010-10 | Watt | | ^ ::: ^ Watt*³ | W | DIN 1301-1:2010-10 | Watt | | ||
- | ^ ::: ^ Kilowatt*³ | kW | DIN 1301-1:2010-10 | KiloWatt | | + | ^ ::: ^ Kilowatt*³ | kW | DIN 1301-1:2010-10 | Kilowatt | |
^ Temperature ^ Degrees Celsius | °C | DIN 1301-1:2010-10 | Celsius | | ^ Temperature ^ Degrees Celsius | °C | DIN 1301-1:2010-10 | Celsius | | ||
^ ::: ^ Degrees Fahrenheit | °F | [NIST-19] | Fahrenheit | | ^ ::: ^ Degrees Fahrenheit | °F | [NIST-19] | Fahrenheit | | ||
Line 681: | Line 690: | ||
^ Electricity ^ Volt*³ | V | DIN 1301-1:2010-10 | Volt | | ^ Electricity ^ Volt*³ | V | DIN 1301-1:2010-10 | Volt | | ||
^ ::: ^ Ampere*³ | A | DIN 1301-1:2010-10 | Ampere | | ^ ::: ^ Ampere*³ | A | DIN 1301-1:2010-10 | Ampere | | ||
+ | ^ ::: ^ Nanoampere*⁶ | nA | DIN 1301-1:2010-10 | NanoAmpere | | ||
+ | ^ ::: ^ Microampere*⁶ | µA | DIN 1301-1:2010-10 | MicroAmpere | | ||
+ | ^ ::: ^ Milliampere*⁶ | mA | DIN 1301-1:2010-10 | MilliAmpere | | ||
+ | ^ ::: ^ Kiloampere*⁶ | kA | DIN 1301-1:2010-10 | KiloAmpere | | ||
+ | ^ ::: ^ Megaampere*⁶ | MA | DIN 1301-1:2010-10 | MegaAmpere | | ||
+ | ^ ::: ^ Gigaampere*⁶ | GA | DIN 1301-1:2010-10 | GigaAmpere | | ||
^ ::: ^ Ohm*³ | Ω | DIN 1301-1:2010-10 | Ohm | | ^ ::: ^ Ohm*³ | Ω | DIN 1301-1:2010-10 | Ohm | | ||
- | ^ ::: ^ Ampere per centimeter*⁴ | A/cm | - | AmperePerCentimeter | | + | ^ ::: ^ Nanoohm*⁶ | nΩ | DIN 1301-1:2010-10 | NanoOhm | |
- | ^ ::: ^ Ampere per meter*⁴ | A/m | - | AmperePerMeter | | + | ^ ::: ^ Microohm*⁶ | µΩ | DIN 1301-1:2010-10 | MicroOhm | |
- | ^ ::: ^ Millitesla*⁴ | mT | - | MilliTesla | | + | ^ ::: ^ Milliohm*⁶ | mΩ | DIN 1301-1:2010-10 | MilliOhm | |
+ | ^ ::: ^ Kiloohm*⁶ | kΩ | DIN 1301-1:2010-10 | KiloOhm | | ||
+ | ^ ::: ^ Megaohm*⁶ | MΩ | DIN 1301-1:2010-10 | MegaOhm | | ||
+ | ^ ::: ^ Gigaohm*⁶ | GΩ | DIN 1301-1:2010-10 | GigaOhm | | ||
+ | ^ ::: ^ Ampere per centimeter*⁴ | A/cm | – | AmperePerCentimeter | | ||
+ | ^ ::: ^ Ampere per meter*⁴ | A/m | – | AmperePerMeter | | ||
+ | ^ ::: ^ Millitesla*⁴ | mT | – | MilliTesla | | ||
^ ::: ^ Tesla*⁴ | T | - | Tesla | | ^ ::: ^ Tesla*⁴ | T | - | Tesla | | ||
+ | ^ ::: ^ Volt*³ | V | DIN 1301-1:2010-10 | Volt | | ||
+ | ^ ::: ^ Nanovolt*⁶ | nV | DIN 1301-1:2010-10 | NanoVolt | | ||
+ | ^ ::: ^ Microvolt*⁶ | µV | DIN 1301-1:2010-10 | MicroVolt | | ||
+ | ^ ::: ^ Millivolt*⁶ | mV | DIN 1301-1:2010-10 | MilliVolt | | ||
+ | ^ ::: ^ Kilovolt*⁶ | kV | DIN 1301-1:2010-10 | KiloVolt | | ||
+ | ^ ::: ^ Megavolt*⁶ | MV | DIN 1301-1:2010-10 | MegaVolt | | ||
+ | ^ ::: ^ Gigavolt*⁶ | GV | DIN 1301-1:2010-10 | GigaVolt | | ||
+ | ^ Sound ^ Phon*⁵ | phon | – | Phon | | ||
+ | ^ ::: ^ Sone*⁵ | sone | – | Sone | | ||
^ Level ^ Decibel*³ | dB | DIN 5493:2013-10 | Decibel | | ^ Level ^ Decibel*³ | dB | DIN 5493:2013-10 | Decibel | | ||
^ Auxiliary units ^ Number (of pieces)*³ | pcs = Stk. | – | Piece | | ^ Auxiliary units ^ Number (of pieces)*³ | pcs = Stk. | – | Piece | | ||
Line 691: | Line 721: | ||
^ ::: ^ Percent*¹ | % | DIN 5466:1983-02 | Percent | | ^ ::: ^ Percent*¹ | % | DIN 5466:1983-02 | Percent | | ||
^ ::: ^ Mol*³ | mol | DIN 1301-1:2010-10 | Mol | | ^ ::: ^ Mol*³ | mol | DIN 1301-1:2010-10 | Mol | | ||
- | | NIST-19: National Institute of Standards and Technology, Gaithersburg, Maryland, USA: NIST Handbook 44 : Specifications, Tolerances, and Other Technical Requirements for Weighing and Measuring Devices (Appendix C. General Tables of Units of Measurement) 2019.\\ *¹ Available from program version 1.2.0.23\\ *² Available from program version 1.3.9.5\\ *³ Available from program version 1.3.9.8\\ *⁴ Available from program version 2.1.1 ||||| | + | | NIST-19: National Institute of Standards and Technology, Gaithersburg, Maryland, USA: NIST Handbook 44 : Specifications, Tolerances, and Other Technical Requirements for Weighing and Measuring Devices (Appendix C. General Tables of Units of Measurement) 2019.\\ *¹ Available from program version 1.2.0.23\\ *² Available from program version 1.3.9.5\\ *³ Available from program version 1.3.9.8\\ *⁴ Available from program version 2.1.1\\ *⁵ Available from program version 2.10.0\\ *⁶ Available from program version 4.2.0 ||||| |
\\ | \\ | ||
Line 813: | Line 843: | ||
</WRAP> | </WRAP> | ||
<WRAP column half> | <WRAP column half> | ||
- | {{ :en:infra-convert:user:terms:mehrfachmerkmale_dupliziert.png?nolink&800 |}} | + | {{ :en:infra-convert:user:terms:mehrfachmerkmale_erneut_gestempelt.png?nolink&800 |}} |
</WRAP> | </WRAP> | ||
</WRAP> | </WRAP> | ||
Line 1070: | Line 1100: | ||
<WRAP rightalign> | <WRAP rightalign> | ||
**Go to previous page**\\ | **Go to previous page**\\ | ||
- | More > [[en:infra-convert:user:collectdrw|Create test plans from a collective drawing]] | + | More > [[en:infra-convert:user:ic_cec_cal|From the drawing to the measuring program in ZEISS CALYPSO]] |
</WRAP> | </WRAP> | ||
- | \\ | + | **Go to next page**\\ |
+ | More > [[en:infra-convert:faq|Frequently asked questions and answers]] | ||
\\ | \\ | ||