~~NOTOC~~ | ~~NOTOC~~ | ||
- | {{ :en:icon_uebersetzung_in_arbeit.png?nolink&150 |}} | + | <WRAP noprint> |
+ | |||
+ | > User manual #@IC_HTML@# > Export drawing from the CAD system > Siemens PLM | ||
+ | |||
+ | </WRAP> | ||
+ | |||
+ | ====== NX (from version 10) ====== | ||
+ | |||
+ | ---- | ||
+ | |||
+ | Described are export settings for the CAD system "Siemens NX" from version 10. With the recommended settings you ensure that the drawing file can be read by #@IC_HTML@# in the best possible way. | ||
+ | |||
+ | Basically, it should be noted that fonts must be installed on the respective PC when processing drawing files in an exchange format, such as DXF, DWG or PDF.\\ **See** [[en:infra-convert:user:fonts|Dealing with missing fonts]] | ||
+ | |||
+ | If an export result is not satisfactory despite the configuration recommendations, we will be happy to support you directly. | ||
+ | |||
+ | \\ | ||
+ | |||
+ | <WRAP noprint> | ||
+ | <WRAP group> | ||
+ | <WRAP column 20%> | ||
+ | //**__Content__**// | ||
+ | |||
+ | • [[en:infra-convert:user:cadexp:nx_10#DXF/DWG export]]\\ | ||
+ | • [[en:infra-convert:user:cadexp:nx_10#IGES export]]\\ | ||
+ | • [[en:infra-convert:user:cadexp:nx_10#PDF export]] | ||
+ | |||
+ | \\ | ||
+ | |||
+ | </WRAP> | ||
+ | </WRAP> | ||
+ | </WRAP> | ||
+ | |||
+ | ==== DXF/DWG export ==== | ||
+ | |||
+ | Manufacturer's documentation for DXF/DWG export (from version 12): [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366|Siemens documentation: DXF/DWG export]]. | ||
+ | |||
+ | Recommended configurations: | ||
+ | |||
+ | {{page>en:infra-convert:user:cadexp:dxf_dwg_version_note}} | ||
+ | |||
+ | |< 100% 7.5% 22.5% 70%>| | ||
+ | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Drafting preferences | **File** > **Drafting preferences** > **View** > **Workflow** > **Border** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid629526|{{:en:icon_link.png|}}]]\\ └ Display: **Off**\\ \\ Version 10: Version 12:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_001.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_001.png?direct&0x100|}} | | ||
+ | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_108.png?nolink&50 |}} ^ Load Settings | **File** > **Export** > **AutoCAD DXF/DWG…** > **Load Settings** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366:xid454319|{{:en:icon_link.png|}}]]\\ └ Load From: Settings file (*.def)*\\ \\ * The configuration file should contain the following value assignment: [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid1396811|{{:en:icon_link.png|}}]]\\ └ UGI_GDT_EXPORT_AS_BLOCK = NO\\ \\ The path to the configuration file for the DXF/DWG translator can also be set once by environment variable NX_DXFDWG_DEF. [[https://docs.plm.automation.siemens.com/tdoc/nx/1899/nx_help#uid:xid1128422:index_dataexchange:xid1579771|{{:de:icon_link.png|}}]] | | ||
+ | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_102.png?nolink&50 |}} ^ Input and Output | **File** > **Export** > **AutoCAD DXF/DWG…** > **Input and Output** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366:xid454319|{{:en:icon_link.png|}}]]\\ └ Export To: **DXF** or **DWG**\\ └ Export As: **2D**\\ └ Output to: **Modeling**\\ └ Output to: **Layout***\\ \\ * #@IC_HTML@# Per required\\ \\ Version 10: Version 12: Version 1899:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_002.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_002.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_1899_001.png?direct&0x100|}} | | ||
+ | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_103.png?nolink&50 |}} ^ Data to Export | **File** > **Export** > **AutoCAD DXF/DWG…** > **Data to Export** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366:xid454319|{{:en:icon_link.png|}}]]\\ └ Model Data/Drawing: **Drawing**\\ \\ Version 10: Version 12: Version 1899:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_003.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_003.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_1899_002.png?direct&0x100|}} | | ||
+ | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_104.png?nolink&50 |}} ^ Options | **File** > **Export** > **AutoCAD DXF/DWG…** > **Options** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366:xid454319|{{:en:icon_link.png|}}]]\\ └ DXF/DWG Revision: see "General - DXF/DWG version" above\\ └ Export Spline As: **Spline**\\ └ Remove Overlapping Entities: **No**\\ └ Scale Option: **No Scale**\\ └ Scale Value: **1.0000**\\ \\ Version 10: Version 12: Version 1899:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_004.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_004.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_1899_003.png?direct&0x100|}} | | ||
+ | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_105.png?nolink&50 |}} ^ Fonts | **File** > **Export** > **AutoCAD DXF/DWG…** > **Fonts** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458383:xid458366:xid454319|{{:en:icon_link.png|}}]]\\ └ Text Width: **Use NX Aspect Ratio**\\ └ Text Width (alternative): **Specify Width Factor**, Width Faktor: **1**\\ └ latin_extended: **isocp.shx**\\ \\ Version 10: Version 12: Version 1899:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_005.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_005.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_1899_004.png?direct&0x100|}} | | ||
+ | |||
+ | \\ | ||
+ | |||
+ | ==== IGES export ==== | ||
+ | |||
+ | Manufacturer's documentation for IGES export (from version 12): [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128422:index_xid458385|Siemens documentation: IGES translator]]. | ||
+ | |||
+ | Recommended configurations: | ||
+ | |||
+ | |< 100% 7.5% 22.5% 70%>| | ||
+ | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Drafting Preferences | **File** > **Drafting Preferences** > **View** > **Workflow** > **Border** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid629526|{{:en:icon_link.png|}}]]\\ └ Display: **Off**\\ \\ Version 10: Version 12:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_001.png?direct&0x100|}} {{en:infra-convert:user:cadexp:cadexp_siemens_nx_12_001.png?direct&0x100|}} | | ||
+ | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Files | **File** > **Export** > **Export to IGES Options** > **Files** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid434343|{{:en:icon_link.png|}}]]\\ └ Export from: **Drawings**\\ └ Export to: **IGES file**\\ \\ Version 10:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_011.png?direct&0x100|}} | | ||
+ | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Data for Export | **File** > **Export** > **Export to IGES Options** > **Data for Export** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid434343|{{:en:icon_link.png|}}]]\\ └ Export: **Selected Drawings**\\ \\ Version 10:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_012.png?direct&0x100|}} | | ||
+ | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Advanced | **File** > **Export** > **Export to IGES Options** > **Advanced** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help/#uid:xid434343|{{:en:icon_link.png|}}]]\\ └ NX 3D to 2D options > Enclose facet body: **Yes**\\ └ NX 3D to 2D options > Convert GDT as a group: **No**\\ \\ Version 10:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_013.png?direct&0x100|}} | | ||
+ | |||
+ | \\ | ||
+ | |||
+ | ==== PDF export ==== | ||
+ | |||
+ | Manufacturer's documentation for PDF export (from Version 12): [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:file_fil_exp_pdf_op|Dialog window "Export PDF"]]. | ||
+ | |||
+ | Recommended configurations: | ||
+ | |||
+ | |< 100% 7.5% 22.5% 70%>| | ||
+ | ^ {{ en:infra-convert:user:cadexp:cadexp_siemens_nx_12_101.png?nolink&50 |}} ^ Export PDF | **File** > **Export** > **PDF...** [[https://docs.plm.automation.siemens.com/tdoc/nx/12/nx_help#uid:xid1128416:index_working_with_files:id1354112:file_fil_exp_pdf_op|{{:en:icon_link.png|}}]]\\ └ Source: Select sheets\\ └ Colors: **Black on white**\\ └ Size: **Original size**\\ └ Output text: **Text**\\ └ Export grid images to drawing: **Yes**\\ └ Image resolution: **Medium** to **Hight**\\ \\ Version 10:\\ {{en:infra-convert:user:cadexp:cadexp_siemens_nx_10_021.png?direct&0x100|}} | | ||
+ | |||
+ | <WRAP noprint> | ||
+ | |||
+ | ---- | ||
+ | |||
+ | <WRAP group> | ||
+ | <WRAP col2> | ||
+ | |||
+ | <WRAP rightalign> | ||
+ | **Go to previous page**\\ | ||
+ | Export drawing from the CAD system > Siemens PLM > [[en:infra-convert:user:cadexp:nx_6|NX 6]] | ||
+ | </WRAP> | ||
+ | |||
+ | **Go to next page**\\ | ||
+ | Export drawing from the CAD system > Siemens PLM > [[en:infra-convert:user:cadexp:solid_edge_st2|Solid Edge ST2]] | ||
+ | |||
+ | </WRAP> | ||
+ | </WRAP> | ||
+ | |||
+ | </WRAP> |