In the Columns field, the tolerance values are assigned to the nominal dimension intervals (variant A) or the number of decimal places of nominal dimensions (variant B). A column represents a tolerance class (series). Within a column definition, only one of the two assignment variants A or B can be selected.
See also
User’s Guide infra CONVERT > Settings > Project Settings > Tolerance tables
User’s Guide infra CONVERT > User Interface > Function Window > Feature properties
"Columns": [ { "Name": "m", "Fields": [ { "MinValue": 0, "MaxValue": 0.499 }, { "MinValue": 0.499, "MaxValue": 3, "UpperTolerance": 0.1, "LowerTolerance": -0.1 }, { "MinValue": 3, "MaxValue": 1000, }, { "MinValue": 1000, "MaxValue": 2000, "UpperTolerance": 0.5, "LowerTolerance": -0.5, "MaxPercent": 25.0 }, { "MinValue": 2000, "MaxValue": 4000, "UpperTolerancePercent": 0.5, "LowerTolerancePercent": -0.5, "ExtraAmount": 0.6 } ] }, { "Name": "According to digits", "Fields": [ { "MinDigits": 0, "MaxDigits": 0 }, { "MinDigits": 1, "MaxDigits": 1, "UpperTolerance": 0.3, "LowerTolerance": -0.3 }, { "MinDigits": 2, "MaxDigits": 2, "UpperTolerance": 0.10, "LowerTolerance": -0.10 }, { "MinDigits": 3, "MaxDigits": 300, "UpperTolerance": 0.050, "LowerTolerance": -0.050 } ] } ]
Parameter | Type | Value/Content |
---|---|---|
Columns | Field | Contains all the columns in the table |
Fields | Field | Contains the assignments of tolerance values to nominal intervals |
Name | String | Display name that allows the user to clearly assign the tolerance class/series |
Variant A: The numerical value of a nominal dimension is used to assign the tolerance values | ||
MinValue | Decimal | Lower limit (LL) of the nominal dimension interval, value included: LL > Value |
MaxValue | Decimal | Upper limit (UL) of the nominal dimension interval, value included: UL ≤ Value |
Variant B: The number of decimal places after the decimal point of a nominal dimension is used to assign the tolerance values | ||
MinDigits | Integer | Lower limit of the interval of the number of decimal places: 0 x 1 x.x 2 x.xx 3 x.xxx … Note Available from programme version 2.8.0. |
MaxDigits | Integer | Upper limit of the interval of the number of decimal places: 0 x 1 x.x 2 x.xx 3 x.xxx … Note Available from programme version 2.8.0. |
Tolerance values | ||
UpperTolerance | Decimal | Upper limit deviation (UT) as absolute value: UT = Value |
LowerTolerance | Decimal | Lower limit deviation (UT) as absolute value: LT = Value |
UpperTolerancePercent | Decimal | Upper limit deviation (UT) as a percentage of the nominal value (N), figures in percent, result rounded to tenth decimal digit: OT = Value × N |
LowerTolerancePercent | Decimal | Lower limit deviation (LT) as a percentage of the nominal value (N), figures in percent, result rounded to tenth decimal digit: LT = Value × N |
MaxPercent | Decimal | The amounts of the limit deviations are limited to a maximum of this percentage of the nominal value, figures in percent: max(|UT|) = Value × N max(|LT|) = Value × N |
ExtraAmount | Decimal | Surcharge on the limit deviation as absolute value: UTnew = OT + Value UTnew = LT - Value |