Step Action Result
1 Create project Create a new project and name it according to your documentation requirements. In this project, you create the inspection plans for all component variants in the next steps. The project is created and named.
2 Creating a generic test plan 1) Load the drawing sheets and name the first test plan version “Generic”. The generic inspection plan version will contain all characteristics that may occur (in different versions) in the component variants.

In the “Version” input field, put a number in front of the version number with which you can count the variants. This is because the variant inspection plans are mapped with inspection plan versions and these must be differentiated using the “version”.
1) The drawing sheets were loaded. In the example, the generic variant is counted as “0”.
2) Stamp all relevant drawing entries. 2) All relevant characteristics have been created. Entries with code letters are automatically recognized as word specifications, “a - 6H” and “b ±0.3” for example as follows:

3) Change the characteristic properties of these characteristics so that they correspond to the first component variant for which an inspection plan is to be created. 3) All characteristics have been created correctly. The properties of the example characteristics have been changed as follows:

3 Derive variant test plans 1) Create the variant test plans by creating test plan versions. Name them and load the drawing sheets. 1) The variant test plans are created, correctly named and contain the drawing sheets.
2) Now transfer the characteristics from the generic test plan to the variant test plans using the drawing comparison function.

To do this, right-click on a drawing sheet in the variant test plan and choose Compare drawing sheet from the context menu. After executing the Transfer characteristics function, all characteristics should have been transferred directly. Close the drawing comparison again.

See alsoCompare drawings (Basic version) and Compare drawings (Pro version)
2) The variant test plans correspond to the generic test plan.
3) Ändern Sie die variablen Merkmale in den Variantenprüfplänen entsprechend den Vorgaben ab, gegebenenfalls durch Löschen. 3) Die variablen Merkmale aller Variantenprüfpläne wurden mit den Vorgaben abgeglichen.
4 Prüfpläne exportieren Für jede Bauteilvariante können nun die Prüfpläne und gestempelten Zeichnungen exportiert werden.
[5] [Im späteren Verlauf]
Prüfpläne versionieren
Bei Zeichnungsänderungen können Prüfplanversionen direkt vom jeweiligen Variantenprüfplan abgeleitet werden, das heißt es muss kein generischer Prüfplan erstellt werden. Es kann allerdings sinnvoll sein, den generischen Prüfplan weiter zu pflegen. Sollte in eine Bauteilvariante ein vorher ausgeschlossenes Merkmal wieder einbezogen werden, ließe sich dieses aus dem generischen Prüfplan übertragen.