User Tools

Site Tools


en:infra-convert:user:functions:loadicp

This is an old revision of the document!


User manual infra CONVERT > Functions > Test plans

Load old ICP project files


With this function, you have the option to load projects created with the previous software infra - CONVERT (file extension: *.ICP) into a project in infra CONVERT. (Project files saved in infra CONVERT bear the file extension *.ICPX.)

ICP projects are linked to a drawing sheet. However, in infra CONVERT, several drawing sheets can be added to a test plan and the test plan can be versioned. As such, you can load several ICP projects into an ICPX project.

Note infra - CONVERT doesn’t save the drawing file in the project file like infra CONVERT does, instead you can expect to find the file where it was last loaded.


Content

 • Workflow
 • Customization


Workflow

Step Action Result
1 Create test plan version Create a test plan version.

Important In order to avoid conflicts with the characteristic numbering, you should only load ICP projects into empty test plan versions.
A test plan version has been created.
2 Open ICP project file 1) Click on the Add drawing sheet button . 1) The file explorer will be opened.
2) Find where the ICP file is saved and open it. 2a) The stamped drawing sheet and the test characteristics will be added to the test plan version. You can then skip step 3.
2b) If the drawing file cannot be found in the stored path for the ICP file*, the file explorer will be opened again. Please follow the instructions in step 3.

* Possible causes: the name of the drawing file has been changed; the file has been moved or deleted.
[3] Reload drawing file The title line of the file explorer “Look for and open missing file: [<Dateiname>]” shows the file name for the drawing. Navigate to the save location of the drawing file and open it.

Note The file can be reloaded even if the name has been changed.
The stamped drawing sheet and the test characteristics will be added to the test plan version.
4 Continue editing You can continue to edit the loaded data and add additional ICP projects and/or drawing sheets to the test plan version, as required.


Customization

There are no setting options for directly influencing this function.