Administrator’s Guide infra CONVERT > Configuration and Import
The →characteristic classes that are available in infra CONVERT are defined in the parameter file CharacteristicClasses.json. More specifically: these definitions are loaded when a new →project is created and saved in the project file. This means that it is not possible to later change the class definitions for a project.
Important Each class definition has parameters that cannot be changed. If a parameter is missing or faulty, then characteristics assigned to the corresponding class will no longer be recognized by the automatic stamp function. The same is, of course, true for missing definitions.
If you need additional classes, you can append definitions. You are welcome to tell us your wishes, as we are interested in offering the widest possible selection of classes.
During installation, the parameter file CharacteristicClasses is saved at the following location:
%ProgramData%\ELIAS GmbH\infra-convert\JsonData\CharacteristicClasses.json
If another parameter file is to be loaded when starting the program, this can be specified in the startup parameter file (see Configuration and Import > Startup parameter file > Parameter file for characteristic classes).
Unique, internal identifier for the class.
Please do not delete these parameters or change their values.
When creating a class definition: Assign new value!
"Id": "{BEA94EBE-84DE-4653-86A5-DD600A45070E}",
Parameter | Type | Value/Content |
---|---|---|
ID | String | GUID of the class |
Reference to the parent class, if there is one.
Please do not delete these parameters or change their values.
When creating a class definition: assign empty string (“”)!
"ParentClass": "Diameter",
Parameter | Type | Value/Content |
---|---|---|
ParentClass | String | FriendlyName of the parent class, if there is one |
Unique, internal identifier for the class in the form of a “user-friendly name”.
Please do not delete these parameters or change their values.
When creating a class definition: Assign new value!
"FriendlyName": "Linear",
Parameter | Type | Value/Content |
---|---|---|
FriendlyName | String | Unique identifier for the class as descriptive name |
Value of the Q-DAS characteristic size K2009.
Please do not delete these parameters or change their values.
See also
Administrator’s Guide infra CONVERT > Export > Quality test plan format DFD > Converting the classes
User’s Guide infra CONVERT > More > Terms > Class (characteristic-) > ID
"QdasClass": 200,
Parameter | Type | Value/Content |
---|---|---|
QdasClass | String | Value of the Q-DAS class. |
ID of the characteristic class, clearly assigned in infra - CONVERT and infra CONVERT.
Please do not delete these parameters or change their values.
When creating a class definition: Assign the value “Undefined” (ID: -1)!
"OldEliasId": 0,
Parameter | Type | Value/Content |
---|---|---|
OldEliasId | String | ID of the characteristic class |
Unit of measurement assigned to the nominal size.
The listed values can be assigned for the parameter.
"NominalUnit": "Millimeter",
Parameter | Type | Value/Content |
---|---|---|
NominalUnit | String | None No unit assigned Length Micrometer Micrometer (µm) Millimeter Millimeter (mm) Centimeter Centimeter (cm) Decimeter Decimeter (dm)* Meter Meter (m) Microinch Mikroinch (µin) Mil Milliinch (mil) Inch Inch (in) Foot Foot (ft) Yard Yard (yd) Angle Degree Degree (°) Volumen CubicMillimeter Cubic millimeter (mm³)* CubicCentimeter Cubic centimeter (cm³)* CubicDecimeter Cubic decimeter (dm³)* CubicMeter Cubic meter (m³)* Relation PerMillion Per million (pm)* Percent Per cent (%)* Force Newton Newton (N)* DecaNewton Dekanewton (daN)* KiloNewton Kilonewton (kN)* Torque Newtonmeter Newtonmeter (Nm) Spring rate NewtonPerMeter Newton per meter (N/m)* Pressure Millibar Millibar (mbar)* Bar Bar (bar)* Pascal Pascal (Pa)* Hectopascal Hectopascal (hPa)* Kilopascal Kilopascal (kPa)* Megapascal Megapascal (MPa)* Mass/Weight Microgram Microgram (µg)* Milligram Milligram (mg)* Gram Gram (g) Kilogram Kilogram (kg) Ton Ton (t) Grain Grain (gr) Dram Dram (dr) Ounze Ounze (oz) Pound Pound (lb) Time Millisecond Millisecond (ms)* Second Second (s)* Minute Minute (min)* Hour Hour (h)* Frequence PerMillisecond Per Millisecond (1/ms)* PerSecond Per Secund (1/s)* PerMinute Per minute (1/min)* PerHour Per Hour (1/h)* Temperature Celsius Centigrade (°C) Fahrenheit Degrees Fahrenheit (°F) Kelvin Kelvin (K)* * Available from program version 1.2.0.23 |
Unit of measurement assigned to the tolerance limits.
The listed values can be assigned for the parameter.
"ToleranceUnit": "Millimeter",
Parameter | Type | Value/Content |
---|---|---|
ToleranceUnit | String | See Nominal unit > “NominalUnit” |
Internal parameter that governs various characteristic assignments, including the assignment of tolerance tables.
Please do not delete these parameters or change their values.
"ClassGroup": "Length",
Parameter | Type | Value/Content |
---|---|---|
ClassGroup | String | Name of the group. Undefined No group assigned Length Length Angle Angle ChamferEdge Chamfer Roundness Roundness GeometricDimensioningTolerancing Geometric tolerancing Roughness Surface parameters |
The variable “Requirement” is available for the direct export of a test plan to Excel. The structure of the variable depends on the feature class and is defined in this object.
The listed values can be assigned for the parameter.
"RequirementTemplate": "Rz{SPC} {N} {UT} {LT} {REP}",
Parameter | Type | Value/Content |
---|---|---|
RequirementTemplate | String | Sequence of variables, specified in curly brackets, and any intermediate characters. The variables are replaced by corresponding values. If no value is assigned to a variable in the specific case, the variable is omitted. Two or more consecutive spaces are replaced by a space. The following variables are available: CL Characteristic class CLSY Class symbol N Nominal value UT Upper tolerance value LT Lower tolerance value F Tolerance class M Limit (“min.”/“max.”) TXT Value CON Conditions/modificators C comment REP Number of repetitions in der form “(2x)”, “(3x)” etc. SPC Extra space (will not be deleted on duplication) Useful Unicode characters: ⌀□⌳⌲⌒⏤⏥○⌭⌒⌓⫽⟂⦟⌖⭗⌯↗⌰◁ |
Texts can be specified in this object, which are displayed in infra CONVERT depending on the user language set.
The listed values can be assigned for the parameter.
"LocalizedProperties": [ { "Name": "Distance", "Description": "", "LanguageCode": "en" }, ]
Parameter | Type | Value/Content |
---|---|---|
Name | String | Display name for the class |
Description | String | Description text |
LanguageCode | String | Language abbreviation as per ISO 639-1 |