User Tools

Site Tools


en:infra-convert:dev:export:csv
Administrator’s Guide infra CONVERT > Export

CSV test plan format


CSV is a file format with a simple structure. Values are assigned to parameters in columns. Semicolons (“;”) are used as delimiters to separate the values.

Note We recommend the JSONV1 format over the DFD format for connecting with your software package. It includes more transferable information and supports all features of infra CONVERT.

You can trigger the export in the start parameter file; see Configuration and Import > Startup Parameter File > Export quality test plans and stamped drawings.


Content

 • Title line
 • Characteristic data


Title line

Contains general test plan data.

The values are queried from the user interface during export. With the Pro version (and from program version 2.10.0), the test plan attributes can be defined in advance, saved and thus also exported on triggering via start parameter call.

The parameter names are output depending on the language set in the program.

See also
User manual infra CONVERT > Functions > Export > Export test plan > Workflow

User manual infra CONVERT > Settings > Settings > Administration > "Additional attributes for test plan versions" group

Configuration and import > “Settings” Parameter file > List of the settings > “Settings > Administration” menu
Column/Parameter Content
1 Part number Individual string
2 Part description Individual string
3 Part amendment status Individual string
4 Drawing number text Individual string
5 Drawing amendment Individual string
6 Remark Individual string


Characteristic data

Contains all of the test plan data in a fixed order.

Chagnes
From program version 1.3.4.1 there are two important changes. These are necessary to make the export compatible to the CSV export from infra - CONVERT.
1) Column 13 (“Count”) is exported as column 19 now.
2) The parameter names are output depending on the language set in the program.

Columns available up to Version 1.3.3.5:
1 StampText
2 Label
3 Value
4 NominalValue
5 UpperTolerance
6 LowerTolerance
7 UpperLimit
8 LowerLimit
9 CharacteristicType
10 Class
11 Fit
12 Comment
13 ToleranceTable
14 ToleranceTableColumn
15 DrawingQuadrant
16 CharacteristicGraphic
17 CharacteristicTypeId
18 CharacteristicClassId
19 CharacteristicId
20 SpecialCategoryId
21 SpecialCategoryText
22 Tags
23 Requirement
24 PositionX
25 PositionY
26 TargetX
27 TargetY
28 Radius
Column/Parameter Content
1 Stamp text Stamp marking

See User interface > Function windows > Characteristic properties > Settings
2 Label Title (filtered by or converted to ANSI code characters)

See User interface > Function windows > Characteristic properties > Settings
3 Value Value (filtered by or converted to ANSI code characters)

See User interface > Function windows > Characteristic properties > Settings
4 Nominal size Nominal size

See User interface > Function windows > Characteristic properties > Settings
5 Upper tolerance Upper tolerance

See User interface > Function windows > Characteristic properties > Settings
6 Lower tolerance Lower tolerance

See User interface > Function windows > Characteristic properties > Settings
7 Upper Limit Upper limit value/maximum value, calculated from the nominal value and lower tolerance / upper deviation limit when exporting
8 Lower Limit Lower limit value/minimum value, calculated from the nominal value and upper tolerance / lower deviation limit when exporting
9 Type Characteristic type (Variable; Attributive)

See User interface > Function windows > Characteristic properties > Settings
10 Characteristic class Characteristic class

See User interface > Function windows > Characteristic properties > Settings
11 Fit Tolerance class

See User interface > Function windows > Characteristic properties > Settings
12 Comment Comment

See User interface > Function windows > Characteristic properties > Settings
13 Tolerance table Tolerance table

See User interface > Function windows > Characteristic properties > Settings
14 Column Tolerance class or “column”

See User interface > Function windows > Characteristic properties > Settings
15 Field Field

See User interface > Function windows > Characteristic properties > Settings
16 Characteristic Graphic Stamp graphic file name

See User interface > Function windows > Characteristic properties > Settings
17 Characteristic Type ID Type ID (1 = variable; 0 = attributive)

See User interface > Function windows > Characteristic properties > Settings
18 Characteristic class ID ID of the characteristic class as allocated in infra - CONVERT
19 Characteristic ID Unique GUID for the characteristic
20 Count Repetitions

See User interface > Function windows > Characteristic properties > Settings
21 Characteristic category ID ID of the category, for reasons of compatibility with the predecessor software, only the values “0” (for “standard feature”) and “1” are output for all other categories. The GUID of the category is output with column 32.

See More > Kategorie (Merkmal-)
22 Characteristic category Category

See More > Kategorie (Merkmal-)
23 Tag Tags, separated by commas (“,”)

See User interface > Function windows > Characteristic properties > Settings
24 Requirement Requierement

See Administrator’s Guide > Configuration and Import > Parameter file “CharacteristicClasses” > Formatting the “Requirement” export variable
25 Position X X-coordinate of the stamp in pixel
26 Position Y Y-coordinate of the stamp in pixel
27 Stamp Target X X-coordinate of the reference point (target point, origin point) of the stamp in pixel
28 Stamp Target Y Y-coordinate of the reference point (target point, origin point) of the stamp in pixel
29 Stamp Radius Size of the stamp, indicated as radius in pixel
30 Reference Reference

See User interface > Function windows > Characteristic properties > Settings
31 Drawing Sheet File name including file extension of the drawing sheet on which the stamp is located
32 Characteristic category GUID Category GUID

See More > Terms > Category (characteristic-)
33 Unit nominal ID of the unit of the nominal size

See User Manual > More > Terms > Measurement (sizes-)
34 Unit tolerance ID of the unit for the tolerance values

See User Manual > More > Terms > Measurement (sizes-)
35 Class symbol Graphic symbol or indicator

See More > Terms > Class (characteristic-)
36 MinMax Limit dimension in one direction (min., max.)

See Settings > Settings > Characteristics > “Limit values in one direction (min., max.)” group
37 Modifiers Modifiers

See Terms > More > Specification operators and modifiers (ISO GPS)

Go to previous page
Export > DFD test plan format (ASCII transfer format)

Go to next page
Export > Drawing and stamp graphics

en/infra-convert/dev/export/csv.txt · Last modified: 2023/08/02 12:04 by me