The templates for →stamps that are assigned to the characteristic categories are defined in the parameter file “StampTemplates.json” (see Configuration and Import > Parameter file "SpecialCategories"). More specifically: these definitions are loaded when a new →project is created and saved in the project file. This means that it is only in the project itself possible to later change the stamp templates for a project.
During installation, the parameter file “StampTemplates.json” is saved at the following location:
%ProgramData%\ELIAS GmbH\infra-convert\JsonData\StampTemplates.json
If another parameter file is to be loaded when starting the program, this can be specified in the startup parameter file (see Configuration and Import > Startup parameter file > Parameter file for stamp templates).
Export project settings
You can export the current project settings as project template files (“CharacteristicTags.json”, “SpecialCategories.json” and “StampTemplates.json”) from the infra CONVERT user interface. (Available from programme version 2.4.1.)
Siehe User Manual > Settings > Project Settings > Tags > Save/Export
Unique, internal identifier for the stamp template.
To create a new template, you can simply use any GUID generator.
"Id": "bf69c190-4bcc-4c2c-9ed1-c67328f4f90e",
Parameter | Type | Value/Content |
---|---|---|
ID | String | GUID of the stamp template |
Size of the stamp in an absolute, CAD-internal unit.
See also
User Manual > Settings > Project settings > Stamp templates
"Radius": 2.0,
Parameter | Type | Value/Content |
---|---|---|
Radius | Double | Value for the radius |
Geometry of the stamp symbol.
See also
User Manual > Settings > Project settings > Stamp templates
"Form": 0,
Parameter | Type | Value/Content |
---|---|---|
Shape | Integer | One of these predefined symbols: 0 VDA symbol 1 Circle 2 Triangle 3 Square 4 Diamond 5 Hexagon 6 Triangle in circle |
Orientation of the stamp relative to the drawing specification if it is generated automatically.
"DefaultPosition": 0,
Parameter | Type | Value/Content |
---|---|---|
DefaultPosition | Integer | Position: 0 Standard (upper right) 1 Upper right 2 Right 3 Lower right 4 Bottom 5 Lower left 6 Left 7 Upper left 8 Top Note From program version 2.4.1 the standard position changes from top right to right. |
Minimum distance of a stamp to a drawing specification, from which a connecting line is marked (in an absolute, CAD-internal unit).
See also
User Manual > Settings > Project settings > Stamp templates
"MinDistanceForConnectionLine": 2.0,
Parameter | Type | Value/Content |
---|---|---|
MinDistanceForConnectionLine | Double | Value for the minimum distance |
Thickness or width with which the connection line is drawn (in an absolute, CAD internal unit)
Note Available from programme version 2.4.1.
See also
User Manual > Settings > Project settings > Stamp templates
"MinDistanceForConnectionLine": 2.0,
Parameter | Type | Value/Content |
---|---|---|
ConnectionLineThickness | Double | Value for the line thickness. 0 Hairline |
Distance of a stamp to a drawing specification, if it is generated automatically (in an absolute, CAD-internal unit).
"DistanceToText": 2.0,
Parameter | Type | Value/Content |
---|---|---|
DistanceToText | Double | Value for the distance |
Opacity of the entire stamp.
Note From program version 2.4.1 onwards, the alpha channel should only be given in colour value, see Color. If it is specified with this parameter Alpha, the alpha value is replaced or added to the colour specification.
See also
User Manual > Settings > Project settings > Stamp templates
"Alpha": 255,
Parameter | Type | Value/Content |
---|---|---|
Alpha | Integer | Value for the opacity (255: opaque to 0: completely transparent). |
Filling of the stamp interior with the color white.
"FillStamp": true,
Parameter | Type | Value/Content |
---|---|---|
FillStamp | Boolean | true Filled false Not filled |
Characters written in the stamp label in front of the stamp number
"Prefix": "",
Parameter | Type | Value/Content |
---|---|---|
Prefix | String | Preceding string. |
Characters written in the stamp label after the stamp number.
"Suffix": "",
Parameter | Type | Value/Content |
---|---|---|
Suffix | String | Following string. |
Texts can be specified in this object, which are displayed in infra CONVERT depending on the user language set.
"LocalizedProperties": [ { "Name": "VDA stamp in blue", "Description": "VDA stamp in blue", "LanguageCode": "en" } ],
Parameter | Type | Value/Content |
---|---|---|
Name | String | Display name for the stamp template |
Description | String | Description text |
LanguageCode | String | Language abbreviation as per ISO 639-1 |
The color of the stamp symbol is specified in the object Color.
"Color": { "Type": "RGB", "R": 0, "G": 0, "B": 255 }
Parameter | Type | Value/Content |
---|---|---|
Type | String | Color system: RGB Red-Green-Blue ARGB Alpha-Red-Green-Blue |
A | Integer | Value for the alpha channel (0 … 255, wiht 0 = fully transparent) |
R | Integer | Value for the red color channel (0 … 255) |
G | Integer | Value for the green color channel (0 … 255) |
B | Integer | Value for the blue color channel (0 … 255) |
The following describes the process for deinstalling, reinstalling (installing after previous deinstallation) and installing (without previous deinstallation) infra CONVERT using the parameter file “StampTemplates.json”. Essential preconditions are: the file is at the location where it was installed, and has not been renamed.
See also Introduction > Overview (program version 2) > Installation/Uninstallation
Uninstallation
The file is deleted.
Reinstallation
An existing file is overwritten.
Installation
An existing file is overwritten.