infra CONVERT
blue DAT • infra DAT
mdm TOOL
infra CONVERT
blue DAT • infra DAT
mdm TOOL
This is an old revision of the document!
Administrator’s Guide infra CONVERT > Configuration and Import
The templates for →stamps that are assigned to the characteristic categories are defined in the parameter file StampTemplates.json (see Configuration and Import > Parameter file "SpecialCategories"). More specifically: these definitions are loaded when a new →project is created and saved in the project file. This means that it is only in the project itself possible to later change the stamp templates for a project.
During installation, the parameter file StampTemplates is saved at the following location:
%ProgramData%\ELIAS GmbH\infra-convert\JsonData\StampTemplates.json
If another parameter file is to be loaded when starting the program, this can be specified in the startup parameter file (see Configuration and Import > Startup parameter file > Parameter file for stamp templates).
Content
• ID
• Radius
• Shape
• Orientation
• Minimum distance for connection line
• Distance
• Opacity
• Fill stamp
• Prefix
• Suffix
• Display text
• Color
Unique, internal identifier for the stamp template.
To create a new template, you can simply use any GUID generator.
"Id": "{bf69c190-4bcc-4c2c-9ed1-c67328f4f90e}",
Parameter | Type | Value/Content |
---|---|---|
ID | String | GUID of the stamp template |
Size of the stamp in an absolute, CAD-internal unit.
"Radius": 2.0,
Parameter | Type | Value/Content |
---|---|---|
Radius | Double | Value for the radius |
Geometry of the stamp symbol.
"Form": 0,
Parameter | Type | Value/Content |
---|---|---|
Shape | Integer | One of these predefined symbols: 0 VDA symbol 1 Circle 2 Triangle 3 Square 4 Diamond 5 Hexagon |
Orientation of the stamp relative to the drawing specification if it is generated automatically.
"DefaultPosition": 0,
Parameter | Type | Value/Content |
---|---|---|
DefaultPosition | Integer | Position: 0 Upper right 1 Lower right 2 Lower left 3 Upper left |
Minimum distance of a stamp to a drawing specification, from which a connecting line is marked (in an absolute, CAD-internal unit).
"MinDistanceForConnectionLine": 2.0,
Parameter | Type | Value/Content |
---|---|---|
MinDistanceForConnectionLine | Double | Value for the minimum distance |
Distance of a stamp to a drawing specification, if it is generated automatically (in an absolute, CAD-internal unit).
"DistanceToText": 2.0,
Parameter | Type | Value/Content |
---|---|---|
DistanceToText | Double | Value for the distance |
Opacity of the entire stamp.
"Alpha": 255,
Parameter | Type | Value/Content |
---|---|---|
Alpha | Integer | Value for the opacity (255: opaque to 0: completely transparent). |
Filling of the stamp interior with the color white.
"FillStamp": true,
Parameter | Type | Value/Content |
---|---|---|
FillStamp | Boolean | true Filled false Not filled |
Characters written in the stamp label in front of the stamp number
"Prefix": "",
Parameter | Type | Value/Content |
---|---|---|
Prefix | String | Preceding string. |
Characters written in the stamp label after the stamp number.
"Suffix": "",
Parameter | Type | Value/Content |
---|---|---|
Suffix | String | Following string. |
Texts can be specified in this object, which are displayed in infra CONVERT depending on the user language set.
"LocalizedProperties": [ { "Name": "VDA stamp in blue", "Description": "VDA stamp in blue", "LanguageCode": "en" } ],
Parameter | Type | Value/Content |
---|---|---|
Name | String | Display name for the stamp template |
Description | String | Description text |
LanguageCode | String | Language abbreviation as per ISO 639-1 |
The color of the stamp symbol is specified in the object Color.
"Color": { "Type": "RGB", "R": 0, "G": 0, "B": 255 }
Parameter | Type | Value/Content |
---|---|---|
Type | String | Color system |
R | Integer | Value for the red color channel (0 … 255) |
G | Integer | Value for the green color channel (0 … 255) |
B | Integer | Value for the blue color channel (0 … 255) |
Go to previous page
Configuration and Import > Parameter file "Uiaccess"
Go to next page
Configuration and Import > Tolerance tables