The startup parameter file is opened by transferring adjacent request parameter “parameter” by executing infra CONVERT. The value of the parameter is the absolute or relative path*¹ to the startup parameter file, here as an example of the syntax: “C:/Windows/Temp/StartParameterFile.json”
InfraConvertWPF.exe -parameter="C:/Windows/Temp/StartParameterFile.json"
The start parameter file summarizes all available call parameters except for the following*². The “forceConfigDir” call parameter can be used to specify a different storage location for the directory with configuration and template files. This is created by default during installation under “%ProgramData%/ELIAS GmbH/infra-Convert” and searched there if the parameter “forceConfigDir” is not passed.
InfraConvertWPF.exe -forceConfigDir="C:/ProgramData/ELIAS GmbH/infra-Convert"
Both parameters can also be transferred at the same time:
InfraConvertWPF.exe -parameter="..." -forceConfigDir="..."
Note to *¹ Up to program version 1.3.5.5, only absolute paths can be specified, both as values of the initial startup parameter and within the startup parameter file.
Note to *² The configuration and template directory can only be defined from program version 1.3.7.0 with this call parameter. When using it, make sure that you also adapt the paths for the directory with Excel template files (parameter ExcelReportsPath) and the directory with tolerance tables (parameter ToleranceTablePath) in the configuration file “settings.json”.
This chapter explains the structure of the startup parameter file. The file may contain any part of the transfer values presented here, but it must adhere to the provisions for setting up a JSON file.
You can find a complete example of a startup parameter file here: Appendix > Example startup parameter file
A self-contained set of parameter files for direct testing can be downloaded from the link below.
Unpack the ZIP archive in the folder “C:/Windows/Temp/” and execute infra CONVERT with reference to the start parameter file contained in it. You can pass the start parameter e. g. with the included Windows batch file.
Content
• Setting the language
• Open or create project
• Open or create quality test plan
• Transfer drawing
• Export quality test plans and stamped drawings
• Invoke function
• Zoom on stamp
• Settings
• Parameter file for tags
• Parameter file for characteristic classes
• Parameter file for characteristic categories
• Parameter file for stamp templates
• Parameter file for showing/hiding/locking control elements
• Editing characteristics
• Editing tags
Use the LanguageCode field to specify the language of the user interface of infra CONVERT.
Without this code, the default language set in the operating system will automatically be used. If it is not supported by infra CONVERT, English will always be set.
"LanguageCode":"de",
Parameter | Type | Value/Content |
---|---|---|
LanguageCode | String | de German en English fr French it Italian es Spanish ru Russian |
With the Project field, specify that an existing project should open or a new project be created when infra CONVERT is launched.
See also
User’s Manual infra CONVERT > Functions > Projects > Create new project
User’s Manual infra CONVERT > Functions > Projects > Open project
User’s Manual infra CONVERT > Functions > Projects > Save project
"Project": { "Path": "C:/Users/user1/Desktop/test.icpx", "Name":"Beispiel Projekt", "Action":"Open" }
Parameter | Type | Value/Content |
---|---|---|
Path | String | Path to the location with the file name; the directory names must be separated by slash characters (“/”) or double backslash characters (“\\”). |
Name | String | Project title (ignored when opening) |
Action | String | Open Opens an existing project Create Creates a new project |
With the InspectionPlanVersion field, specify that an existing quality test plan should open or a new quality test plan be created when infra CONVERT is launched.
A new quality test plan can only be created when a project has already been created.
"InspectionPlanVersion": { "Name": "Zeichnungsstand", "Version": "0", "Action": "Create" }
Parameter | Type | Value/Content |
---|---|---|
Name | String | Quality test plan title (ignored when opening) |
Version | Decimal | Version of the quality test plan (ignored when opening) |
Action | String | Open Opens an existing quality test plan Create Creates a new quality test plan |
Use the Files field to import any number of drawing sheets in a quality test plan when infra CONVERT is launched.
See also
User’s Manual infra CONVERT > Functions > Drawings > Import drawings
User’s Manual infra CONVERT > More > Terms > Drawing date format
"Files": [ { "Path":"C:/Users/user1/Desktop/drawing_1.dxf" }, { "Path":"C:/Users/user1/Desktop/drawing_2.igs" }, { "Path":"C:/Users/user1/Desktop/drawing_3.pdf" }, { "Path":"C:/Users/user1/Desktop/drawing_4.icp" }, { "Path":"https://ftp.elias-gmbh.de/fictional_path/example.dwg" } ]
Parameter | Type | Value/Content |
---|---|---|
Path | String | Path to the location with the file name; the directory names must be separated by slash characters (“/”) or double backslash characters (“\\”). Note It is possible to specify the path in URL notation, beginning with “https” and “http”, from program version 1.3.5.7 onwards. |
With the Targets field, specify that when the Save project command is executed in quality test plans and/or stamped drawings and/or drawing details in infra CONVERT should be exported.
Note We recommend you use the quality test plan format JSONV1 because it supports all the characteristics of infra CONVERT.
See also
Administrator’s Manual infra CONVERT > Export > Quality test plan format JSONV1
Administrator’s Manual infra CONVERT > Export > Quality test plan format DFD
"Targets": [ { "Format":"JSONV1", "LanguageCode":"de", "Path":"C:/Temp/testplan.json", "InspectionPlanVersionExportMode": "Last" }, { "Format":"CSV", "Path":"C:/Temp/CSV/testplan.csv" }, { "Format":"DFD", "Path":"C:/Temp/DFD/", "ExportHint": "MultiFileExport" }, { "Format":"DFD", "Path":"C:/Temp/DFD/testplan.dfd", "ExportHint": "CombinedExport" }, { "Format":"PDF", "Path":"C:/Temp/PDF/" }, { "Format":"Png", "Path":"C:/Temp/Graphics/", { "Format":"Jpg", "Path":"C:/Temp/Graphics/", "Mode":"Drawing" }, { "Format":"Bmp", "Path":"C:/Temp/Graphics/", "Mode":"Stamps" } ]
The following applies for the JSONV1 quality test plan format:
Parameter | Type | Value/Content |
---|---|---|
Format | String | JSONV1 |
LanguageCode | String | de German en English |
Path | String | Path to the location with the file name; the directory names must be separated by slash characters (“/”) or double backslash characters (“\\”). |
InspectionPlanVersionExportMode | String | Implicit Export the test plan version addressed by the “InspectionPlanVersion” parameter when the start parameter is called (default behavior, is applied if the parameter is not specified). Last The most recent inspection plan version at the time of export Note The “newest” inspection plan version is the inspection plan version with the highest lexical version number. Note This parameter is available as of program version 1.3.7.2 |
The following applies for the CSV quality test plan format:
Parameter | Type | Value/Content |
---|---|---|
Format | String | CSV |
Path | String | Path to the location with the file name; the directory names must be separated by slash characters (“/”) or double backslash characters (“\\”). |
InspectionPlanVersionExportMode | String | Implicit Export the test plan version addressed by the “InspectionPlanVersion” parameter when the start parameter is called (default behavior, is applied if the parameter is not specified). Last The most recent inspection plan version at the time of export Note The “newest” inspection plan version is the inspection plan version with the highest lexical version number. Note This parameter is available as of program version 1.3.7.2 |
The following applies for the DFD quality test plan format:
Parameter | Type | Value/Content |
---|---|---|
Format | String | DFD |
Path | String | Path to the location without a file name; the directory names must be separated by slash characters (“/”) or double backslash characters (“\\”). |
InspectionPlanVersionExportMode | String | Implicit Export the test plan version addressed by the “InspectionPlanVersion” parameter when the start parameter is called (default behavior, is applied if the parameter is not specified). Last The most recent inspection plan version at the time of export Note The “newest” inspection plan version is the inspection plan version with the highest lexical version number. Note This parameter is available as of program version 1.3.7.2 |
ExportHint | String | MultiFileExport Export partial test plans to separate DFD files (default behavior, applied if parameter is not specified) CombinedExport Export partial test plans to collective DFD file Note This parameter is available as of program version 1.3.7.2 |
This applies to drawing exports in PDF und SVG format:
Parameter | Type | Value/Content |
---|---|---|
Format | String | PDF All drawing sheets each as a PDF file SVG All drawing sheets each as a SVG file |
Path | String | Path to storage location, for multiple export (“MultiFileExport”) without file name, for combined export (“CombinedExport”) with file name; the directory names must be separated by slash characters (“/”) or double backslash characters (“\\”). |
InspectionPlanVersionExportMode | String | Implicit Export the test plan version addressed by the “InspectionPlanVersion” parameter when the start parameter is called (default behavior, is applied if the parameter is not specified). Last The most recent inspection plan version at the time of export Note The “newest” inspection plan version is the inspection plan version with the highest lexical version number. Note This parameter is available as of program version 1.3.7.2 |
This applies to drawing exports in PNG, JPG, BMP, TIF und GIF format:
Parameter | Type | Value/Content |
---|---|---|
Format | String | Png All drawing sheets and/or all stamped characteristics in extracts as PNG files Jpg All drawing sheets and/or all stamped characteristics in extracts as JPG files Bmp All drawing sheets and/or all stamped characteristics in extracts as BMP files Tif All drawing sheets and/or all stamped characteristics in extracts as TIF files Gif All drawing sheets and/or all stamped characteristics in extracts as GIF files |
Mode | String | Drawing Only drawing sheets Stamps Only stamp graphics If Mode is not specified, drawing and stamp graphics are exported together |
Path | String | Path to the location without a file name; the directory names must be separated by slash characters (“/”) or double backslash characters (“\\”). |
InspectionPlanVersionExportMode | String | Implicit Export the test plan version addressed by the “InspectionPlanVersion” parameter when the start parameter is called (default behavior, is applied if the parameter is not specified). Last The most recent inspection plan version at the time of export Note The “newest” inspection plan version is the inspection plan version with the highest lexical version number. Note This parameter is available as of program version 1.3.7.2 |
With the Mode field, call up a function in infra CONVERT when it is launched. The function will not be executed, but it will be opened and is thus directly available to the user. The following functions are currently available (more will follow):
The following applies for the Tag tool function:
"Mode": { "Name": "AddCharacteristicTag", "ItemId": "{5D1110CA-6093-4381-B372-CF983D515044}" }
Parameter | Type | Value/Content |
---|---|---|
Name | String | AddCharacteristicTag |
ItemId | String | GUID of the tag |
The following applies for the Drawing comparison function:
"Mode":{ "Name":"CompareDocuments", "SourceInspectionPlanVersion":{ "Name":"Neuer Prüfplan", "Version":"A" }, "TargetInspectionPlanVersion":{ "Name":"Neuer Prüfplan", "Version":"B" }, "SourceDocumentOriginalFileName":"ez-29002675001-84-0_1.dxf", "TargetDocumentOriginalFileName":"ez-29002675001-84-a_1.dxf" }
Parameter | Type | Value/Content |
---|---|---|
Name | String | CompareDocuments |
SourceInspectionPlanVersion | Field | |
└ Name | String | Name of the source test plan version |
└ Version | String | Version number of the source test plan version |
TargetInspectionPlanVersion | Field | |
└ Name | String | Name of the target test plan version |
└ Version | String | Version number of the target test plan version |
SourceDocumentOriginalFileName | String | File name of the source drawing sheet |
TargetDocumentOriginalFileName | String | File name of the target drawing sheet |
Available from
program version 1.2.0.21
When opening a project, you can set the view in the drawing window to a specific stamp. infra CONVERT focuses the stamp and zooms in so far that the corresponding drawing entry including the surrounding area is fitted into the window.
Each stamp in an ICPX file is assigned a GUID. Pass it in the field ZoomToStampGuid. If characteristics have been linked by transfer or merge in the drawing comparison, you can also transfer the ID of the original stamp, then the system zooms to the corresponding stamp of the latest inspection plan version.
If ICP files are loaded into a project, the GUIDs of the stamps may not be known. In this case, you can also pass the stamp ID. Use the field ZoomToStampIcpId. In this field you must also specify the test plan version and the name of the ICP file, because the ID from infra - CONVERT is only valid within an ICP project.
Note
infra CONVERT can also be used as a viewer with the zoom functionality. Disable user interface controls (see “Configuration and Import > Parameter file "UiAccess"”) to prevent data corruption. To view ICP files, temporarily create an ICPX project and load the ICP file into a test plan version.
The GUID of the stamp is known:
"ZoomToStampGuid":{ "Id":"{56422575-2376-497f-b633-8dbe06626fab}" }
Parameter | Type | Value/Content |
---|---|---|
Id | String | GUID of the stamps |
Only the ID of the stamp in the ICP file is known:
"ZoomToStampIcpId":{ "InspectionPlanVersion":{ "Name":"Neuer Prüfplan", "Version":"A" }, "DocumentName":"ez-29002675001-84-0_1.icp", "Id":"3" }
Parameter | Type | Value/Content |
---|---|---|
InspectionPlanVersion | Feld | |
└ Name | String | Title of the test plan version |
└ Version | String | Version number |
DocumentName | String | Name of the ICP file |
Id | String | ICP ID |
The path to the parameter file Settings.json is specified in the Settings field. infra CONVERT obtains the global settings from this file.
Please note Changes made by the user in the user interface are not written to the “settings.json” loaded here, but to the “settings.json” in the CommonAppData directory whose path is defined in the “settings.json” with the parameter “CommonAppDataPath”.
See also
Administrator’s Manual infra CONVERT > Run program > Parameter file "Settings"
Administrator’s Manual infra CONVERT > Configuration and Import > “Settings” Parameter file > List of the settings > Settings with no control elements in user interfaces
User’s Manual infra CONVERT > Settings > Settings > General
"Settings": { "Path": "C:/ProgramData/ELIAS GmbH/infra-CONVERT/Settings.json", }
Parameter | Type | Value/Content |
---|---|---|
Path | String | Path to the location and file name; the directory names must be separated by slash characters (“/”) or double backslash characters (“\\”). |
The path to the parameter file CharacteristicTags.json is specified in the CharacteristicTagsDefinition field. infra CONVERT obtains the definitions for tags with which the project is saved from this file.
If this file does not exist, it will be created with the default settings.
See also
Administrator’s Manual infra CONVERT > Run program > Parameter file "CharacteristicTags"
User’s Manual infra CONVERT > Settings > Project settings > Tags
"CharacteristicTagsDefinition": { "Path": "C:/Users/user1/AppData/CharacteristicTags.json", }
Parameter | Type | Value/Content |
---|---|---|
Path | String | Path to the location and file name; the directory names must be separated by slash characters (“/”) or double backslash characters (“\\”). |
The path to the parameter file CharacteristicClasses.json is specified in the CharacteristicClassesDefinition field. infra CONVERT obtains the definitions for characteristic classes with which the project is saved from this file.
See also
Administrator’s Manual infra CONVERT > Configuration and Import > Parameter file "CharacteristicClasses"
User’s Manual infra CONVERT > More > Terms > Class (characteristic-)
"CharacteristicClassesDefinition": { "Path": "C:/Users/user1/AppData/CharacteristicClasses.json" }
Parameter | Type | Value/Content |
---|---|---|
Path | String | Path to the location and file name; the directory names must be separated by slash characters (“/”) or double backslash characters (“\\”). |
The path to the parameter file SpecialCategories.json is specified in the SpecialCategoriesDefinition field. infra CONVERT obtains the definitions for characteristic categories with which the project is saved from this file.
See also
User’s Manual infra CONVERT > Settings > Project settings > Categories
User’s Manual infra CONVERT > More > Terms > Category (characteristic)
"SpecialCategoriesDefinition": { "Path": "C:/Users/user1/AppData/SpecialCategories.json" }
Parameter | Typ | Value/Content |
---|---|---|
Path | String | Path to the location and file name; the directory names must be separated by slash characters (“/”) or double backslash characters (“\\”). |
The path to the parameter file StampTemplates.json is specified in the StampTemplatesDefinition field. infra CONVERT obtains the definitions for stamp templates which are saved with the project, from this file.
See also
Administrator’s Manual infra CONVERT > Configuration and Import > Parameter file "StampTemplates"
User’s Manual infra CONVERT > Settings > Project settings > Stamp templates
"StampTemplatesDefinition": { "Path": "C:/Users/user1/AppData/StampTemplates.json" }
Parameter | Typ | Value/Content |
---|---|---|
Path | String | Path to the location and file name; the directory names must be separated by slash characters (“/”) or double backslash characters (“\\”). |
The UiAccessDefinition field sets the path to the UiAccess.json parameter file. It can be used to control which control elements in the infra CONVERT user interface should be visible, locked or hidden.
If the file does not exist, it will be created with the usual default settings.
See also
Administrator's Manual infra CONVERT > Configuration and Import > Parameter file "UiAccess"
"UiAccessDefinition": { "Path": "C:/Users/user1/AppData/UiAccess.json", }
Parameter | Typ | Value/Content |
---|---|---|
Path | String | Path to the location and file name; the directory names must be separated by slash characters (“/”) or double backslash characters (“\\”). |
The Characteristics field allows you to communicate to infra CONVERT which characteristics have changed in an existing project since it was last edited. If new tags were assigned in a CAQ system, for instance, this method allows them to also be reassigned in the project.
"Characteristics": [ { "CharacteristicId": "66a58671-5b11-4135-8210-32701be6f4a5", "Action":"Update", "CharacteristicTags": [ "5D1110CA-6093-4381-B372-CF983D515044", "24C41CA8-871C-456E-B082-22EC2A20216D" ], "SpecialCategory":"{3E298F8F-02F1-49CD-82BF-BCDF26DA11FE}" }, { "CharacteristicId": "b29bfa80-294a-4ca6-ae8f-81f4e63a39be", "Action":"Update", "CharacteristicTags": [ "5D1110CA-6093-4381-B372-CF983D515044" ], "SpecialCategory":"{3E298F8F-02F1-49CD-82BF-BCDF26DA11FE}" } ]
Parameter | Type | Value/Content |
---|---|---|
CharacteristicId | String | GUID of the characteristic |
Action | String | Update Action: update |
CharacteristicTags | String | GUID of the tag |
SpecialCategory | String | GUID of the category |
The CharacteristicTags field allows you to communicate to infra CONVERT which tags have been added or changed since the last time a project was edited.
"CharacteristicTags": [ { "Action": "AddOrUpdate", "CharacteristicTag":{ "Id": "69A6290C-89E2-438B-A2D7-F0AA645409CA", "Priority": 2, "FriendlyName": "TagThree", "Color": { "Type": "RGB", "R": 0, "G": 255, "B": 0 }, "LocalizedProperties": [ { "Name": "Tag Three ", "Description":"", "LanguageCode": "en" }, { "Name": "Kennzeichnung Drei", "Description": "", "LanguageCode": "de" } ] } }, { "Action": "AddOrUpdate", "CharacteristicTag":{ "Id": "5D1110CA-6093-4381-B372-CF983D515044", "Priority": 2, "FriendlyName": "", "Color": { "Type": "RGB", "R": 0, "G": 0, "B": 255 }, "LocalizedProperties": [ { "Name": "Tag Four ", "Description":"", "LanguageCode": "en" }, { "Name": "Kennzeichnung Vier", "Description": "", "LanguageCode": "de" } ] } } ]
Parameter | Type | Value/Content |
---|---|---|
Action | String | AddOrUpdate Add or change a tag, depending on whether or not the tag exists |
CharacteristicTag | Feld | Contains all the properties of the tag |
└ Id | String | GUID of the tag |
└ Priority | Integer | Rank in the order of existing tags |
└ FriendlyName | String | Name of the tag |
└ Color | Feld | Stamp color of a characteristic with this tag |
└ Type | String | RGB “RGB” color system |
└ R | Integer | Color value for red: 0…255 |
└ G | Integer | Color value for green: 0…255 |
└ B | Integer | Color value for blue: 0…255 |
└ LocalizedProperties | Feld | Name of the tag (possible for multiple languages) |
└ Name | String | User-friendly name of the tag |
└ Description | String | Description of the tag (optional) |
└ LanguageCode | String | de German en English |
Go to previous page